5.2 Restoring Factory Defaults
The system is designed to function using the factory defaults shown in Figure 5-1. This settings
will display when the controller is powered on. If these defaults are changed, the system may
not function properly. There is no single key or command sequence to reset all factory settings.
To reset these settings proceed as follows:
5.2.1 CamID
When the controller is powered on, the CamID will be displayed. The CamID should be 001. If
necessary, reset the CamID to 001. To reset the CamID:
1. From the start up screen (Figure 5-1), press [1].
2. Press [Cam]. The CamID will change to 001. The setting is saved.
5.2.2 MonID
When the controller is powered on, the MonID will be displayed. The MonID should be 001. If
necessary, reset the MonID to 001. To reset the MonID:
1. From the start up screen (Figure 5-1), press [1].
2. Press [Mon]. The MonID will change to 001. The setting is saved.
TP-5406201-B
July 2017
CamID: 001
MonID: 001
Protocol:
Pelco-d
Baudrate:
2400
Figure 5-1 Start Up Screen
I
PI-35
OSITION
T
P
5-3