The following procedures describe how to swap the removable plug and the plug plate on the
bottom egress.
To swap the removable plug and plug plate:
1. Ensure there is no power to the positioner.
2. Loosen the (4) bolts securing the removable plug to the side of the mounting pedestal.
3. Carefully pull away the removable plug and gently pull out the attached wires and gasket
behind it (Figure 2-4).
Plug
Connector
Figure 2-4 Carefully Pull Out the Removable Plug, Gasket, and Attached Wires
4. Disconnect the wires from the positioner. The wires are connected to the positioner with
a quick connect (Figure 2-5).
TP-5406201-B
July 2017
Gasket
Wires
Quick
Connect
Figure 2-5 Quick Connect