HSP 137 Replacing a disk drive in a Primary Storage Shelf or an Expansion Storage Shelf
Note: Disk drives are hot-swappable. The storage shelf does not need to be powered down when
replacing a disk drive.
To locate and identify the storage shelf that has the faulty disk drive
1
Remove the bezel of the storage unit.
2
Verify that the unit contains a failed disk drive by checking the Drive Drawer Service Action
Required LED on the front of the drawer. If a fault is detected, the amber Drive Drawer Service
Action Required LED is on.
Number
Definition
1
Drive Drawer Status Service Action Allowed LED
2
Drive Drawer Status Service Action Required LED
3
Drive 1 Activity LED
4
Drive 2 Activity LED
5
Drive 3 Activity LED
6
Drive 4 Activity LED
7
Drive 5 Activity LED
8
Drive 6 Activity LED
9
Drive 7 Activity LED