Hardware Part Replacement Procedure
Removing and replacing faulty Primary Storage Shelf and Expansion Storage
Shelf disk drives
This section describes how to remove and replace faulty storage disk drives in a Primary Storage
Shelf or Expansion Storage Shelf.
Requirements
ESD wrist strap
3-TB or 6-TB hot-swappable disk drive for the storage shelves
Caution: Each storage shelf must have disk drives of the same capacity. You cannot mix 3TB
and 6TB disk drives within one shelf.
The size of the disk drive is printed on the label. See the following image for the location:
Caution: You must complete a drive swap within three minutes. Leaving the drive slot open for longer
than three minutes can result in the appliance overheating and cause other components to fail.
Caution: Swap one drive at a time only. Removing more than one drive at one time can affect system
functionality.
HSP 137 Replacing a disk drive in a Primary Storage Shelf or an Expansion Storage Shelf