Maintenance and care
Finishing the cleaning programme
Cleaning the outside of the machine
Close the stopcock in the water pipe in the building. There may be up to three stopcocks depending on
the size of the machine and its level of equipment.
Switch off the mains disconnector in the building or the built-in mains disconnector on the machine.
MTF series machines:
Clean the filters in the loading zone.
Clean the floor filter in the loading zone.
Clean the loading and unloading zones.
MTR series machines:
Clean the connected table system.
Clean the exterior surfaces with a stainless steel cleaner and stainless steel polish.
8.1.3
Checking external water treatment
Check whether sufficient regeneration salt has been added.
8.2 Every month
8.2.1
Cleaning the roof cleaning jet
8.2.2
Cleaning the exhaust air system
Remove the grease filter.
Clean the exhaust air pipes with a water hose and hot water. The water flows back into the tank in the last
zone. If necessary, use a degreasing agent and a long brush.
18
Close the doors.
Touch button (7).
All tanks are drained, washed out with hot water and drained again.
The machine switches itself off afterwards.
INFO: There is a roof cleaning jet in each of the machine's zones.
Cleaning
Unscrew the knurled screw (1).
Remove the roof cleaning jet (2) and rinse it out thoroughly with
water.
Check that the jet is free of blockages.
Re-install the roof cleaning jet. The marking "TOP" must point
upwards. The part number must be able to be read from below.