Inserting Vacuum Pick; Inserting Nozzle - Pace TF 1500 Operation And Maintenance Manual

Bga rework station
Table of Contents

Advertisement

c. Inserting/changing vacuum pick.
i. Insert proper size vacuum pick. The diameter needs to be smaller than
d. Inserting/changing nozzle. (Figure 3b)
i. Insert proper size nozzle. The nozzle should be 3 mm larger than the
www.paceworldwide.com
the top of the component. The pick screws into place. (Figure 3a)
Figure 3a
outside of the component. If the proper nozzle size cannot fit onto the
PCB due to adjacent components being to close, use a smaller nozzle or
keep the nozzle approximately 1mm above the part. Align the nozzle
under the square hole in the reflow head. The nozzle snaps into place.
The nozzle can be positioned with the front surface parallel to the PCB or
at a diagonal by moving the lever by the nozzle housing.
Figure 3b
System Operations Manual
Vacuum pick
Nozzle
Page 8 of 38