b.
Then through the small cable trough.
c.
Then through the back-most cable trough
When securing the cables with the Velcro straps located on the front slide bar, ensure
Caution -
that the Velcro straps do not wrap around the bottom of the slide bar. Otherwise, expansion and
contraction of the slide bar might be hindered when the server is extended from the rack and
returned to the rack.
Ensure that the secured cables do no extend above the top or below the bottom
16.
of the storage server to which they are attached; otherwise, the cables might
snag on other equipment installed in the rack when the storage server is
extended from the rack or returned to the rack.
17.
If necessary, bundle the cables with additional Velcro straps to ensure that they
stay clear of other equipment. If you need to install additional Velcro straps,
wrap the straps around the cables only, not around any of the CMA components;