b.
Apply upward pressure to the outside edge of each hinge connector until the
hinge connector comes off the hinge [frame 3].
c.
Repeat
Step 2a
d.
One at a time, position each round cable cover horizontally over the hinges,
and align the hinge connectors with the hinges.
e.
Using your thumb, apply downward pressure on each hinge connector to
snap the hinge connector into place.
Swing the cable covers down and press down on the cable cover handle to
f.
lock them into the closed position.
3.
Ensure that the six Velcro straps are threaded into the CMA as shown in the
CMA Components figure at the beginning of this procedure.
Ensure that the two Velcro straps located on the front slide bar are threaded through the
Note -
opening in the top of the slide bar. This prevents the Velcro straps from interfering with the
expansion and contraction of the slide bar when the storage server is extended out of the rack
and returned into the rack.
4.
Extend the storage server approximately 13 cm (5 inches) out of the front of the
rack.
5.
Take the CMA to the back of the equipment rack, and ensure that you have
adequate room to work at the back of the storage server.
References to "left" or "right" in this procedure assume that you are facing the back of
Note -
the equipment rack.
Throughout this installation procedure, support the CMA and do not allow it to hang
Note -
under its own weight until it is secured at all four attachment points.
6.
To install the CMA connector A into the left slide-rail:
a.
Insert CMA connector A into the front slot on the left slide-rail until it locks
into place with an audible click [frames 1 and 2].
The connector A tab (see callout 1) goes into the slide-rail front slot (callout 2).
and
Step 2b
to remove all three cable covers.
Install the Cable Management Arm (Optional)
Installing the Storage Server Into a Rack
51