Locate elbow and pipe plugs in ports of selector valve. Label corresponding
7 7 ) )
ports in new selector valve, and remove elbow and plugs from old valve and
place into labeled ports in new valve.
Assemble in reverse order.
8 8 ) )
7 7 . . 1 1 4 4 D D r r a a i i n n V V a a l l v v e e s s
7 7 . . 1 1 4 4 . . 1 1 M M a a n n u u a a l l O O p p e e r r a a t t i i o o n n O O f f D D r r a a i i n n V V a a l l v v e e
Should the actuation motor of a drain valve cease to operate, the drain valve can be
operated manually as follows.
Support control panel bottom with one hand, loosen retaining screw at panel
1 1 ) )
top, let panel slide down slightly to clear screw, push panel back up, then swing
panel top out and down.
62
S S H H O O C C K K H H A A Z Z A A R R D D T T o o a a v v o o i i d d e e l l e e c c t t r r i i c c a a l l
s s h h o o c c k k , , m m o o v v e e t t h h e e p p o o w w e e r r s s w w i i t t c c h h t t o o o o f f f f a a n n d d
d d i i s s c c o o n n n n e e c c t t m m a a i i n n c c i i r r c c u u i i t t b b r r e e a a k k e e r r , , o o r r u u n n - -
p p l l u u g g c c a a r r d d a a t t w w a a l l l l r r e e c c e e p p t t a a c c l l e e . .