Henny Penny LVE-202 Technical Manual page 32

Open fryer (electric) reduced oil capacity
Hide thumbs Also See for LVE-202:
Table of Contents

Advertisement

Program Code
S S P P - - 5 5 8 8
S S P P - - 5 5 9 9
NOTE: Not all Special Program Mode functions are discussed in this section. To
ensure proper operation of fryer, please consult Henny Penny Corp. before changing
any of these settings. For information on these functions, contact Service Department
at 1-800-417-8405, or 1-937-456-8405.
5 5 . . 2 2 . . 1 1 S S P P - - 1 1 Z Z o o n n e e - - U U S S A A / / N N o o n n - - U U S S A A
Press ✓ and "SP-1 ZONE" shows in the display. Use the left and right arrows to
1 1 ) )
set the default set-points to USA specifications or non-USA specifications.
5 5 . . 2 2 . . 2 2 S S P P - - 2 2 S S y y s s t t e e m m I I n n i i t t i i a a l l i i z z a a t t i i o o n n
Press the down arrow and "SP-2 DO SYSTEM INIT" scrolls in left display. To
1 1 ) )
reset the controls to factory default settings, press and hold ✓ and controls
count down "IN 3", "IN 2", "IN 1". Once display shows "-INIT-" "*DONE*", the
controls are reset to factory defaults.
5 5 . . 2 2 . . 3 3 S S P P - - 3 3 2 2 n n d d L L a a n n g g u u a a g g e e
Press the down button and "SP-3 LANGUAGE" scrolls in left display. Use the
1 1 ) )
left and right arrows to set to: ENGLISH; FRANCAIS; CAN FREN; ESPANOL;
PORTUG; DEUTSHE; SVENSKA; РУССКИИ or -NONE-.
NOTE: By setting a second language in the controls, 2 languages can now be
easily chosen by pressing the info button twice during normal operation. Once
language shows in the right display. Pressing ✓ selects the language in the
display.
5 5 . . 2 2 . . 4 4 S S P P - - 4 4 2 2 n n d d V V o o l l u u m m e e
Press the down arrow; "SP-4" "2ND VOLUME" flashes on the left display. Press
1 1 ) )
the left and right arrows to select the desired 2nd volume.
NOTE: By setting a second volume in the controls, 2 volumes can now be easily
chosen by pressing the info button three times during normal operation. Once
volume settings shows in the right display. To select the volume, press ✓ button
under the desired volume.
5 5 . . 2 2 . . 5 5 S S P P - - 5 5 Q Q u u i i c c k k C C o o n n f f i i g g u u r r a a t t i i o o n n
Press the down arrow and "SP-5 QUICK CONFIG" shows in display. Use the left
1 1 ) )
and right arrows to change the menu selection in the controls to: CHKN+FSH;
FF/HBR; CHKN, or EMPTY.
5 5 . . 2 2 . . 6 6 S S P P - - 6 6 P P o o l l i i s s h h D D u u r r a a t t i i o o n n
Press the down arrow and "SP-6 POLISH" shows in left display. Use product
1 1 ) )
buttons to change polish time, from 5 minutes to maximum of 10 minutes.
5 5 . . 2 2 . . 7 7 S S P P - - 7 7 D D r r a a i i n n V V a a l l v v e e
Press the down arrow and "SP-7 DRAIN VALVE" scrolls in left display. Use the
1 1 ) )
left and right arrows to change right display to show "NORMAL" or "MANUAL".
"NORMAL" means the drain valves are controlled electronically and "MANUAL"
means the drain valves must be opened by hand.
24
Auto Idle minutes
Idle set point
Description