Display
Cause
"E-82B"
Home switch
failed, Position
switch working.
"E-82C"
Both switches
failed. Valve will
not operate.
"E-82D"
Position switch
failed. Valve will
not operate.
"E-83-A"
Pressure too
high.
"E-83-B"
Pressure too
high.
"E-83-C"
Pressure too high
"E-83-D"
Pressure too
high.
"E-83-E"
Pressure too
high.
"E-83-J"
Bulk JIB FILL
switch on when
pressure too
high.
"E-83-R"
Bulk Dispose
switch on when
pressure too
high.
"E-93A"
24VDC Tripped.
Correction
5 5 . . Check for voltage at the motor connection AIF side. Is
there a voltage of 24VDC? if yes, replace motor. If no,
check harness and AIF board.
Check filter system in Vat #1.
Check filter system in Vat #2.
Check filter system in Vat #3.
Check filter system in Vat #4
Check filter system in Vat #5.
Check JIB fill valves.
Check Bulk Dispose quick-disconnect behind fryer.
Have motors for drain valves and selector valve checked.