PIOU/PIOUS/RSSU/RSIU Setup

DKAdmin/DKBackup PC directly connected to the Strata DK – 50 feet maximum (see
Figure 16
DKAdmin/DKBackup PC connected to Strata DK via Toshiba Data Interface Units – 1000
feet maximum (see
DKAdmin/DKBackup PC remote modem connected to Strata DK system external
modem/TTY port (direct modem to modem call)(see
DKAdmin/DKBackup PC remote modem connected to Strata DK system built-in IMDU,
RMDS (or external modem) – voice call first, then modem to modem connection (see
Figure 19
DKAdmin/DKBackup PC remote modem connected to Strata DK modem pool – then auto
dial modem pool DIU to Strata DK DIU/TTY port (see
DKAdmin/DKBackup PC DIU/DIU modem pool connected to Strata DK system modem
– voice call first, then modem to modem connection (see
DKAdmin/DKBackup PC DIU/DIU modem pool connected to Strata DK system modem
– DIU to DIU connection, then modem to modem connection (see
PIOU/PIOUS/RSSU/RSIU Setup
To check the DKAdmin/DKBackup communications setup
1. From the Options/System Installation/Communication Setup menu, verify that the proper
COM port is selected and that the communications parameters are set as follows:
Communications port:
Baud rate:
Parity:
Data bits:
Stop bits:
2. PIOU or PIOUS PCB installed on Strata DK which is connected to DKAdmin/DKBackup
PC: if using an IMDU, verify that the switch SW2 is set for 1200 bps (LED CD4 off) and
that SW3 is set to "MODEM."
If connecting an external modem, PDIU-DS, or PC COM port directly to the TTY
modular jack, verify SW2 is set to the "TTY" position.
3. RSSU does not support the IMDU built-in modem or SMDR, and it has no option
switches. Its communication parameters (TTY port) are always 1200 bps, even parity, 7
data bits, 1-stop bit.
4. Use Program 03 to identify the PCB slot that contains the PCB with the TTY port or
modem that will be used (Code 41 for PIOU, PIOUS, or RSSU or Code 49 for RSIU).
5. Use Program 76 if RSIU/RSIS/RMDS is used to connect with the DKAdmin/DKBackup
PC.
6. Use Program 77-1 (LED 14 and 15) if IMDU or RMDS is used to connect to the
DKAdmin/DKBackup PC.
128
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
on
Page
130).
Figure 17
on
Page
on
Page
133).
COMX (X = 1, 2, 3 or 4)
1200 (If using RSIU TTY port or RMDS,
the Baud rate can be higher than 1200 bps.)
Even
7
1
131).
Figure 18
Figure 20
Figure 21
on
Page
132).
on
Page
135).
on
Page
137).
Figure 22
on
Page
139).
DKAdmin/DKBackup