SERVICE RAM ADDRESSES
8000AE (0051AE)- 8000AF[H] (0051AF[H])- User parameter 14 to 15
Not used
8000B9[H] (0051B9[H]) - User function 62 settings
Bits 0 to 3: Not used
Bit 4: RDS operation
Bits 5 and 6: Not used
Bit 7: Daylight saving time
8000BA[H] (0051BA[H]) - User function 62 settings
Bit 0: Not used
Bit 1: Dialing type
Bits 2 to 7: Not used
8000BB[H] (0051BB[H]) - PSTN access number for loop start
Access number
Hex value to program (BCD)
0
ò
0
00
ò
99
8000C8 (0051C2) to 8000DB[H] (0051C5[H]) - RTI (Max. 20 characters - ASCII) - Note 1
8000DC (0051D6) to 8000EF[H] (0051E9[H]) - CSI (Max. 20 characters - ASCII)
8000F0 (0051EA) to 80010F[H] (005209[H]) - TTI (Max. 32 characters - ASCII) - Note 1
800110[H] (00520A[H]) - Number of CSI characters (Hex)
Note 1: If the number of characters are less than the maximum (20 for RTI, 32 for TTI), add a
stop code (FF[H]) after the last character.
800111 to 80011F[H] (BRO only) - Service station's fax number (Service function 13)
80012F[H] (00520B[H]) - ID code (low - Hex)
800130[H] (00520C[H]) - ID code (high - Hex)
800141 to 800147[H] (BRO only) - Last power off time (Read only)
800140[H] - Year (BCD)
800141[H] - Month (BCD)
800142[H] - Day (BCD)
800143[H] - 00: Monday, 01: Tuesday, 02: Wednesday, ....... , 06: Sunday
800144[H] - Hour
800145[H] - Minute
800146[H] - Second
The following counters are listed on the System Parameter List. The names used on the re-
port are given in brackets.
0: Not acceptable
1: Acceptable for the limit specified by
system switch 03
0: Disabled, 1: Enabled
0: Pulse dialing (10 pps),
1: Tone (DTMF) dialing
F0
ò
F0
00
ò
99
4-64