SERVICE TABLES AND PROCEDURES
BIT SWITCHES
G3 Switch 09 - Not used (do not change the settings)
G3 Switch 0A
FUNCTION
Maximum allowable carrier
drop during image data
reception
0
Bit 1
Bit 0
Value (ms)
0
0
200
1
0
1
400
1
0
800
1
1
Not used
2
Not used
3
Maximum allowable frame
interval during image data
4
reception.
0: 5 s
1: 13 s
5
Not used
Reconstruction time for the
first line in receive mode
0: 6 s
1: 12 s
6
Not used
7
G3 Switch 0B - Not used (do not change the settings)
G3 Switch 0C
FUNCTION
Pulse dialing method
Bit 1 Bit 0 Setting
0
0
0
Normal (P=N)
0
1
Oslo (P=10 - N)
1
1
0
Sweden (N+1)
1
1
Not used
2
Not used
to
7
G3 Switch 0D - Not used (do not change the settings)
G3 Switch 0E - Not used (do not change the settings)
G3 Switch 0F - Not used (do not change the settings)
COMMENTS
These bits set the acceptable modem carrier drop time.
Try using a longer setting if error code 0-22 is frequent.
Do not change the settings.
This bit set the maximum intervals between each EOL
signal (end-of-line) or intervals between each ECM
frame from the other end.
Try using a longer setting if error code 0-21 is frequent.
Do not change the settings.
When the sending terminal is controlled by a computer,
there may be a delay in receiving page data after the
local machine accepts set-up data and sends CFR. If
this occurs, set this bit to 1 to give the sending
machine more time to send data.
Refer to error code 0-20.
Do not change the settings.
COMMENTS
P = Number of pulses sent out, N = Number dialed.
Do not change the settings.
4-32
August 7th, 1995

Advertisement

Table of Contents
loading

This manual is also suitable for: