2. MAJOR UNIT REPLACEMENT
2.3 REPLACING THE RIBBON MOTORS
CAUTION:
NEVER separate the ribbon motors from the attaching plate because doing so will change their
adjustment.
1) Disconnect the connector and remove the two SM-3x5B screws to detach the ribbon motors.
Attaching Plate
Ribbon Motor
Screw (SM-3x5B)
Connector (Red)
Connector (Black)
2) Replace the ribbon motors, then align the dowels to attach the ribbon motors. Reassemble in the
reverse order of removal.
2.4 REPLACING THE TAKE-UP MOTOR
CAUTION:
NEVER separate the take-up motor from the bracket because doing so will change the adjustment.
NOTE: The following procedure can be employed without removing the top cover and left side cover.
1) Remove the four FL-3x5 screws to detach the motor cover.
2) Remove the connector for the rewind full sensor (LED).
3) Disconnect the connector from the CN1 on the PWM PC board and remove the two FL-3x5 screws
to detach the take-up motor.
PWM PC Board
Bracket
Take-up Motor
4) Replace the take-up motor, then align the dowels to attach the motor cover and rewind full sensor
(Tr).
FLOIL G-488
Ribbon Motor
Screw (SM-3x5B)
Connector
FLOIL G-488
Attaching Plate
Connector (CN1)
Screw (FL-3x5)
2-5
2.3 REPLACING THE RIBBON MORTORS
FLOIL
Dowels
Fig. 2-8
Motor Cover
Screw (FL-3x5)
Fig. 2-9
EM18-33010A