3.MAIN UNIT REPLACEMENT
2.4 Replacing the Ribbon Motors
CAUTION!
DO NOT separate the Ribbon Motor from the Attachment Plate, as doing so will change their
adjustment.
1. Disconnect the connectors and remove the two SMW-3x5 Screws to detach the Ribbon Motors.
FLOIL G-488
Attachment Plate
Ribbon Motor
SMW-3x5 Screw
2. Replace the Ribbon Motors with new ones. When installing the Ribbon Motors, align the dowel pins with
the dowel holes in the Ribbon Motor Attachment Plate.
3. Reassemble in the reverse order of removal.
Ribbon Motor Attachment Plate
Connector (White)
SWM-3x5 Screw
Connector (Black)
FLOIL G-488
2- 7
EO18-33017
2.4 Replacing the Ribbon Motors
Dowel Pins