Parameters Related To Terminal Function Selection - Toshiba TOSVERT VF-nC1 Instruction Manual

Industrial inverter (for three-phase inductive motors)
Table of Contents

Advertisement

Specified frequency reach signal: 8
FM/OUT terminal (
FL terminal (
Specified frequency reach reverse signal: 9
FM/OUT terminal (
FL terminal (
* FM/OUT terminal function selection (
Note: Activate
signals to the FLA, FLC and FLB terminals.
6.2

Parameters related to terminal function selection

6.2.1
Changing the function of the VI/S3 terminal
: Analog input/logic input function selection
•Function
This parameter is used to switch the function of the VI/S3 terminal between analog signal input
and contact signal input.
■Parameter setting
Title
Analog input/logic
input function
selection
* To use the VI/S3 terminal as a contact input terminal in sink connection, be sure to insert an
adequate resistor* between P15 and VI/S3. (* Recommended resistance: 4.7 kΩ-1/4W)
6.2.2
Keeping an input terminal function always active
: Always active function selection (ST)
•Function
This parameter allows you to select a function you want to keep always active (ON). (Only one
function can be selected.)
■Parameter setting
Title
Always active function
selection (ST)
6.2.3
Changing the function of an input terminal
: Input terminal selection 1 (F)
: Input terminal selection 2 (R)
: Input terminal selection 3 (S1)
: Input terminal selection 4 (S2)
: Analog input/logic input function selection *1
: Input terminal selection 5 (VI/S3)
Output frequency [Hz]
+ 2.5Hz
- 2.5Hz
0
)
)
)
)
) : 0 (Output frequency)
to output signals to the FM/OUT terminal, or set
Function
0: Voltage signal, 1: Current signal,
2: Contact input
Function
0~40, 49, 54~57 (See Section 11.)
F-3
Time [sec]
ON
OFF
ON
OFF
Adjustment range
Adjustment range
E6581090
to 8 or 9 to output
6
Default setting
0
Default setting
1 (ST)