Appendix B - Technical Data; Ddcs Link - ABB NCAN-02 Installation And Startup Manual

Canopen adapter module
Table of Contents

Advertisement

DDCS Link

NCAN-02 Installation and Start-up Guide
Appendix B – Technical Data
Compatible Devices: All ABB Fieldbus Adapter modules,
ABB ACS 400, ACS/ACP/ACC/ACF 600, ACS 800, ACS 1000,
DCS 400/500/600 drives
Size of the Link: 2 stations
Medium: Fibre optic cable
• Construction: Plastic core, diameter 1 mm, sheathed with
plastic jacket
• Attenuation: 0.31 dB/m
• Maximum Length between Stations: 10 m
• Specifications:
Parameter
Storage Temperature
Installation Temperature
Short Term Tensile Force
Short Term Bend Radius
Long Term Bend Radius
Long Term Tensile Load
Flexing
Topology: Point-to-point
Serial Communication Type: Asynchronous, half Duplex
Transfer Rate: 4 Mbit/s
Protocol: Distributed Drives Communication System (DDCS)
Connectors: Blue – receiver; grey – transmitter
Minimum
Maximum
-55
+85
-20
+70
50
25
35
1
1000
Unit
°C
°C
N
mm
mm
N
cycles
B-1