3. Meridian as a dive computer
Along these lines, Meridian employs a
variable ideal ascent rate: its value ranges
between 7..20m/min / 23..66ft/min and the
actual breakdown by depth range is listed
in the chart below.
DEPTH
m
0
6
12
18
23
27
31
35
39
44
50
If the ascent rate is greater than 110% of
the ideal value the sLoW symbol appears.
For ascent rates higher than 140%, the
sLoW symbol starts to flash.
Slow symbol
Meridian also provides an audible alarm
in case of ascent rates exceeding 110%:
the intensity of the alarm increases in direct
proportion to the degree that the ideal
ascent rate is exceeded.
In case of a fast ascent, Meridian may
require a decompression stop even within
the no-stop phase because of the danger
of microbubble formation.
42
ASC SPEED
ft
m/min
ft/min
0
7
23
20
8
26
40
9
29
60
10
33
75
11
36
88
13
43
101
15
49
115
17
56
128
18
59
144
19
62
164
20
66
From great depth a slow ascent may
cause heightened saturation of tissues
and an extension of both decompression
duration and total ascent time. At shallow
depth, a slow ascent may shorten the
decompression duration.
Excessive ascent rates for longer periods
are entered in the logbook.
Warning
The ideal ascent rate must not be exceeded at
any time since this could lead to microbubbles
in the arterial circulation which could cause
serious injury or death.
The alarm persists for as long as the ascent
rate is 110% or more of the ideal ascent
rate.
3.11.8
MOD/ppO
2
Warning
• The MOD should not be exceeded.
Disregarding the alarm can lead to oxygen
poisoning.
• Exceeding a ppO
of 1.6bar can lead to
2
sudden convulsions resulting in serious
injury or death.
If you exceed the MOD, the depth will start
to flash and in the bottom row the MOD is
displayed so you can see by how much you
have exceeded it. In addition, Meridian will
beep incessantly. Both the flashing of the
depth value and the beeping will continue
for as long as you stay deeper than the
MOD.
3.11.9
CNS O
= 100%
2
Warning
When the CNS O
reaches 100% there is
2
danger of oxygen toxicity. Start procedure to
terminate the dive.
Meridian tracks your oxygen uptake via the
CNS O
clock. If the calculated value of
2
SCUBAPRO MERIDIAN
Need help?
Do you have a question about the Meridian and is the answer not in the manual?
Questions and answers