something  did  not  work  as  planned. 
• Diving with two gas mixtures represents a
much higher risk than diving with a single
gas mixture, and mistakes by the diver may
lead to serious injury or death.
• During dives with two gas mixtures, always
make sure you are breathing from the tank
that you intend to breathe from. Breathing
from a high oxygen concentration mix at the
wrong depth can kill you.
• Mark all your regulators and tanks so
that you cannot confuse them under any
circumstance.
• Before each dive and after changing a tank,
ensure that each gas mixture is set to the
correct value for the corresponding tank.
• Get a proper training and certifications to
make multi-gas dives prior of making them.
Meridian enables you to use up to two gas 
mixtures  during  the  dive  (air  and  Nitrox 
only).  The  two  mixtures  are  labeled  1  and 
d,  and  must  be  in  ascending  order  of  the 
oxygen fraction. 
Time
1
Diving with 2 gas mixtures
switching gas mixture during the dive
During the ascent phase, when you reach a 
depth corresponding to the MOD of gas d, 
Meridian will suggest that you perform the 
switch.  An  audible  sequence  goes  off, 
and  the  text  gas d  starts  flashing  on  the 
display together with the value of the MOD. 
You  have  30  seconds  to  respond  to  this 
message, otherwise Meridian will consider 
that Gas d will not be used and adapts the 
decompression  schedule  accordingly.  To 
confirm  the  gas  switch,  press seL/esC
button.
SCUBAPRO MERIDIAN
Warning
d
d
Deco mix
Bottom mix
3. Meridian as a dive computer
F
NOTE: Start breathing from the tank
with the new gas mixture before
confirming a switch.
Warning
Always make sure you are switching to the
intended gas. Failure to do so may result in
serious injury or death.
After  you  confirm  the  switch,  the  text 
gas d  remains  on  the  screen  for  five 
seconds without flashing.
switching back to a gas mixture with
lower oxygen concentration
There may be situations in which you have 
to switch back to Gas 1 from Gas d. This 
can  happen  for  instance  if  you  want  to 
descend again below the MOD for Gas d, 
or  if  for  instance  you  have  run  out  of  Gas 
d  during  the  decompression.  At  this  point 
you can manually initiate the gas switch by 
pressing and holding  SEL/ESC  button. 
Meridian  will  display  the  text  gas 1  and 
its  MOD,  flashing.  At  this  point  press
seL/esC button  to  confirm  the  switch. 
Meridian will display the text gas 1 for five 
seconds  without  flashing  and  adapt  the 
decompression schedule accordingly. 
gas switch not carried out at the
planned depth
If  you  fail  to  confirm  the  change  to  Gas  d 
within  the  30  seconds  of  when  Meridian 
suggested  it,  Gas  d  is  excluded  from 
the  decompression  calculation  and  the 
decompression  schedule  is  adapted 