Surge Suppression/Filtering - Image Sensing Systems RTMS Echo User Manual

Hide thumbs Also See for RTMS Echo:
Table of Contents

Advertisement

Chapter 2:

Surge Suppression/Filtering

Surge Suppression: The CITEL MJ8-POE-B
has been tested and is the recommended
transient suppressor for RTMS Echo sensors.
Figure 2-4: Citel Surge Suppressor
Power over Ethernet surge protector
RJ-45 connection for PoE-A or B
10/100/1000 Mbps compatible
Max DC power:
7.5 VDC for pins 1, 2, 3, 6
60 VDC for pins 4, 5, 7, 8
Max DC current: 1200mA
Frequency: 100 MHz
Bi-directional protection
Shielded enclosure and connectors
Din rail mountable
UL497B listed
RTMS Echo User Guide
Filtering: The COSEL SNR-10-23-DT line noise
filter has been tested and is the recommended
filter for RTMS Echo sensors.
Voltage rating: 50VDC
Current rating: 10A
Leakage current: 50 uA
Capacitance: 0.022 uF
Din rail mountable
RoHS compliant