Activation Character

This sets the character used to trigger scanning when using Character Activation
Mode. On the
value that represents the character you want to use to trigger scanning. Scan the
following bar code, then use the
combination that represents that ASCII character. Scan Save to finish. Default = 12
[DC2]..

End Character Activation After Good Read

After a bar code is successfully detected and read from the scanner, the illumina-
tion can be programmed either to remain on and scanning, or to turn off. When
End Character Activation After Good Read is enabled, the illumination turns off
and stops scanning after a good read. If you scan Do Not End Character Activa-
tion After Good Read, the illumination remains on after a good read. Default = Do
Not End Character Activation After Good Read.
Activation After Good Read

Character Activation Timeout

You can set a timeout for the length of time the illumination remains on and
attempting to decode bar codes when using Character Activation Mode. Set the
length (in milliseconds) for a timeout by scanning the following bar code, then set-
ting the timeout (from 1-300,000 milliseconds) by scanning digits from the
Programming Chart
Default = 30,000 ms.
N3680 Decoded Engine User Guide
ASCII Conversion Chart (Code Page
* Do Not End Character
inside the back cover of this manual, then scanning Save.
Programming Chart
Activation Character
Character Activation Timeout
1252), page 174, find the hex
to read the alphanumeric
End Character Activation After
Good Read
35