41
FF
6A
0013
42
FF
69
0012
43
FF
Output Sequence Editor
Partial Sequence
If an output sequence operation is terminated before all your output sequence cri-
teria are met, the bar code data acquired to that point is a "partial sequence."
Scan Discard Partial Sequence to discard partial sequences when the output
sequence operation is terminated before completion. Scan Transmit Partial
Sequence to transmit partial sequences. (Any fields in the sequence where no data
match occurred will be skipped in the output.)
50
start character match for Code 39, 41h = "A"
termination string for first code
code identifier for Code 128
B - Code 128 sample length (12) plus CR suffix (1) = 13
start character match for Code 128, 42h = "B"
termination string for second code
code identifier for Code 93
C - Code 93 sample length (11) plus CR suffix (1) = 12
start character match for Code 93, 43h = "C"
termination string for third code
Enter Sequence
Transmit Partial Sequence
* Discard Partial Sequence
N3680 Decoded Engine User Guide
Default Sequence