UPC-A Number System

The numeric system digit of a U.P.C. symbol is normally transmitted at the begin-
ning of the scanned data, but the unit can be programmed so it will not transmit it.
Default = On.

UPC-A Addenda

This selection adds 2 or 5 digits to the end of all scanned UPC-A data.
Default = Off for both 2 Digit and 5 Digit Addenda.

UPC-A Addenda Required

When Required is scanned, the scanner will only read UPC-A bar codes that have
addenda. You must then turn on a 2 or 5 digit addenda listed on
Not Required.
N3680 Decoded Engine User Guide
* On
2 Digit Addenda On
5 Digit Addenda On
Required
Off
* 2 Digit Addenda Off
* 5 Digit Addenda Off