Beeper Duration - Good Read; Led - Good Read; Number Of Beeps - Good Read; Number Of Beeps - Error - Honeywell N3680 User Manual

Decoded engine and 2d imager module
Table of Contents

Advertisement

Beeper Duration – Good Read
The beeper duration codes modify the length of the beep the scan engine emits on
a good read. Default = Normal.
LED – Good Read
The LED indicator can be programmed On or Off in response to a good read.
Default = On.
Number of Beeps – Good Read
The number of beeps of a good read can be programmed from 1 - 9. The same
number of beeps will be applied to the beeper and LED in response to a good read.
For example, if you program this option to have five beeps, there will be five beeps
and five LED flashes in response to a good read. The beeps and LED flashes are in
sync with one another. To change the number of beeps, scan the bar code below
and then scan a digit (1-9) bar code and the Save bar code on the
Chart
Number of Beeps – Error
The number of beeps and LED flashes emitted by the scan engine for a bad read or
error can be programmed from 1 - 9. For example, if you program this option to
have five error beeps, there will be five error beeps and five LED flashes in response
32
* Normal Beep
* LED - Good Read On
inside the back cover of this manual. Default = 1.
Number of Good Read Beeps/LED Flashes
LED - Good Read Off
N3680 Decoded Engine User Guide