5.5 PLANNED MAINTENANCE CHECKLIST
It is recommended that you contact your AccuTemp authorized service provider to setup a planned
maintenance program to keep your appliance operating in the most efficient manner. AccuTemp
recommends a minimum of a yearly schedule.
PM DESCRIPTION
Verify that the appliance is level and properly located under the
hood.
Verify that the temperature controller is working properly and
that there are no rips in the overlay.
Check that the splash shield at the top of the control panel
is under the rail provided. If not water and or grease can
migrate and cause possible damage to the internal electronic
components.
Inspect the control compartment for foreign particulate and any
loose wiring connections.
A back draft diverter has been installed at the factory this will
keep scraping from spatulas from dropping down the flue
and will provide addition protection from back drafts that can
effect stand-by burner operation. Check that flue has not
been pushed in resulting in an uneven opening across the flue
passage. Pull flue out so that flue opening is even across width
of appliance.
Verify the operation and condition of the igniter and flame
sense probe assembly. Probes should be cleaned with a wire
brush and/or emery cloth. Caution: DO NOT use any abrasive
that contains silica. This will leave a coating on the flame
sensor that could cause the unit not to light.
Clean all burner orifices, making sure that each orifice is clear
and unobstructed. It may be necessary to use a drill the same
size of the orifice, if very soiled.
Inspect the burner venturi tubes for foreign particulate. Wipe
out with a mild detergent and warm water and rinse with clean
water.
Inspect combustion chamber and the burner tiles. If water
stains are present on tiles check that tiles have no cracks and
haven't sunk into the burner. Replace burners if this condition is
present.
Inspect the ignition wire harness for any evidence of high
temperature degradation or grease build-up on harness
connector. Spray contact cleaner into white connector and
clean mating connector imbedded in ignition module. Coat the
pins with a dielectric grease.
Verify main burner regulator pressures are correct.
Verify flame sense operation