3.9 ELECTRICAL CONNECTIONS
When this appliance is installed with
casters it must be installed with the casters
supplied. A connector complying with
either ANSI Z21.69 - CSA 6.9. It must also
be installed with restraining means to the
connector as specified in the appliance
manufacturer's instructions.
This commercial appliance must
be properly grounded in accordance of
all current National, state and local codes.
Never remove the ground prong of the plug.
3.9.1 ELECTRICAL SUPPLY
The ACCU-STEAM™ griddle has been designed,
manufactured and tested to meet or exceed
the demanding standards of safety set forth by
ANSI Z83.11. To to ensure that this high level
of safety is maintained in your installation, it is
important that you read and understand the
following information before attempting to
plug in your griddle.
3.8.2 ELECTRICAL REQUIREMENTS
Electrical requirements are listed on the
data plate located on the front right of the
control panel. All standard AccuTemp griddles
are supplied with a 6ft (1.83m) cord and
the appropriate UL listed plug that must be
connected to a 15 Amp (120Vac) or a 20 Amp
(208-240Vac) depending on the rating listed
on the data plate. Make sure that the voltage
at your supply receptacle is within ± 10 % of
the voltage listed on the griddle data plate.
Connection to any other voltage may cause
damage to components in the commercial
appliance. The appliance plug must be used
with the appropriate receptacle.
Direct wiring will void the warranty.
MP5017-2002
3.9.3 GROUNDING INSTRUCTIONS
Grounding provides a path for electric current
to reduce the risk of shock. This product
is equipped with a power cord having a
grounding conductor and a grounding plug.
The plug must be plugged into a grounded
receptacle that is installed and grounded
in accordance with local codes, or in the
absence of local codes, with the National
Electric Code, NFPA 70, or the Canadian
Electrical Code, CSA22.2, as applicable.
Under no circumstances shall the grounding
or prong of the plug be cut off or bent to fit
a receptacle other than the one supplied. Do
not use any adapters to fit the receptacle.