4.2.1 PROGRAM SEQUENCE OF
OPERATION
Press the ON/OFF
will start to pre-heat and LED 1 will blink Any
time the appliance is turned on it will operate
and heat to the default set temperature or the
last regulated Non-Preset temperature.
(Factory default is 350°F)
The display will show the current temperature
until the set temperature is met, then LED 1
will go solid. (See FIG 4) The display will go to
a "rdY" display or show the set temperature
depending on the programming when the
appliance was initially installed and setup.
(Factory default is "rdY")
PRESETS
Press the ON/OFF
the griddle will start to pre-heat and LED 1 will
blink .
Press and hold any PRESET KEY
for three seconds or until the LED 2 or LED 3
blinks.
The selected preset LED will blink and the
display will show the current temperature
and increase or decrease depending on the
set temperature until it has reached the set
preset temperature for that preset key and
then go solid and The display will go to a "rdY"
or show the set temperature depending on
the programming when the appliance was
initially installed and setup. The set display
temperature will remain at the set temperature
until the griddle is turned off and back on.
The factory defaults for the preset keys are:
375°F
400°F
MP5017-2002
switch and the griddle
switch (See FIG 8) and
or
Accu-Steam Gas Griddle
4.2.2 MANAGER MODE PROGRAMMING
Prior to using the commercial appliance a few
operational items need to be determined.
Default set temperature
Preset 1 set temperature
Preset 2 set temperature
Operator lockout of set temperatures or
"on the fly" temperature set
Default Set Temperature - is the temperature
that the commercial appliance will heat up to
when turned on.
Preset 1 Set Temperature - is an alternative set
temperature that the commercial appliance
will heat up to when activated from the key-
pad.
Preset 2 Set Temperature - is an alternative set
temperature that the commercial appliance
will heat up to when activated from the key-
pad.
Set Temperature Lockout - If turned on
in the manager mode will lock in the set
temperatures that were last saved in memory.
If not set to active (Loc), the set temperatures
can be set lower or higher than the last saved
value.
To change the preset temps, attend the
following steps:
1. Power the unit on, the display will show the
default temp (factory set to 350°F).
2. Hold the
UP arrow until the display
reading starts to increase.
3. At this point, the
arrows can be used to increase or decrease
the griddle temperature
4. Once the new desired preset point has
been reached. Push and hold the PRESET
button you wish to set this temperature to.
5. The unit will power off.
6. When the unit is powered back on, push
and hold the PRESET button for three
seconds, the new temperature should be
programmed.
UP or
DOWN
22