Seal Replacement (each year or as needed)
Replace the air nozzle's seal if worn or damaged. Replace as needed and/or each year for
preventative maintenance.
If there is any fragrance that leaks during the cartridge installation, clean it carefully with a paper
towel and some ethanol or another alcohol.
Air Filter and Check Valve Replacement
(every 6 months or sooner depending on use)
AirQ 1280 is equipped with a filter and a check valve.
The filter (PN 5251) collects fine dust. Replace every 6 months or sooner depending on use. A layer
of black dust on top of the filtering media is a sign that the filter should be replaced. To replace it,
unscrew the four screws to remove the bracket and exchange the filter after pulling it off the rubber
tubing. Note the small triangle showing the normal air flow direction and position filter accordingly
as shown below.
The check valve (PN 10200) should be replaced every six months. It is also located behind the
bracket. Note the position of the check valve. Replace check valve accordingly as shown below.
Reinstall the bracket and screw the four screws back in place being careful not to strip the threads.
The screws should align and go in easily.
Unscrew to remove bracket
AirQ 1280
Check
Valve
Filter
USER MAINTENANCE
Never touch PCB without
ESD protection.