  • Page 1 P ERFEC T LY S C E N TE D E N V IR O NM E N TS GENIE Updated: 2019-07-18...
  • Page 2: Table Of Contents

    Contents Chapter 6: USER MAINTENANCE Cartridge Change Chapter 1: About Genie Cartridge Change Maintenance Checklist Items Chapter 2: Unpacking Changing an Appliance Chapter 3: MOVING AND STORAGE General Care INSTRUCTIONS Chapter 7: Applications Chapter 4: INSTALLATION Ambient Scenting General Product Marketing...
  • Page 3: Chapter 1: About Genie

    This is not an accident. The scientists and engineers at Prolitec are committed to the highest ecological and human safety standards. This User Guide is easy to read. It is also important to read. Genie is a high-performance appliance that, installed and used correctly, will meet the most demanding requirements.
  • Page 4: Chapter 2: Unpacking

    Unpacking Remove Genie from the container. The following items should be included: 1. Genie Appliance 2. Power Supply 3. Two Keys 4. Mounting Hardware 5. Installation Template Genie Chapter 2 Unpacking...
  • Page 5 2. Unscrew and remove the two screws on the right. 3. Lift the appliance upward, off the mounting screws. 4. Unplug the appliance. 5. Store at -4°F (-20°C) to 158°F (70°C), 5% to 95% humidity Genie Chapter 3 MOVING AND STORAGE INSTRUCTIONS...
  • Page 6: Chapter 4: Installation

    Service Area The service area range of Genie is from 100 to 15,000 cubic (6 to 425 cubic meters). Of course this can vary significantly depending on airflow, number of fresh air changes per hour, temperature, humidity and desired service interval.
  • Page 7: Estimating Cartridge Life

    These settings are suggested as a starting point. Start on the lower end of the range and adjust after one hour. Fragrance type, room size, number of fresh air changes per hour, temperature, humidity and user preference will determine the final setting. Best practice is to use AirQ’s ‘S3 Tool’ at AirQ Tools. Genie Chapter 4 Installation...
  • Page 8: Appliance Location

    See Figure 1. If the smoke drifts out of the room, the Genie appliance should be placed on the wall furthest from the door. See Figure 2. If there is no clear direction that the smoke travels or it travels upward into the air-conditioning return grill, find a position near the air-conditioning supply grill.
  • Page 9: Positioning The Installation Template

    Step 2 – Mounting Kit, Parts and Tools The mounting kit provided with Genie includes an installation template and 4 long round-head screws and 4 wall anchors suitable for plastered drywall. If you have another surface you will need to get anchors suitable for the wall material and screws that work with these anchors.
  • Page 10: Installing The Anchors

    The standard installation is to position the appliance right over the power source, storing the power- supply block and the power cord in the recess in the back of the appliance. To make this easy, do not untie the power cord and take just enough wire to make the connection. Genie Chapter 4 Installation...
  • Page 11: Final Two Screws

    Step 7 – Final Two Screws Secure the appliance to the wall with the final two screws. Step 8 – Replacing the Cover After cartridge installation unit programming, replace the cover and lock it, storing the key in a known location. Genie Chapter 4 Installation...
  • Page 12: Chapter 5: Operating Instructions

    OPERATING INSTRUCTIONS Features and Controls Lock Lock Cover User Interface Locking Air Stem and Air Hose Reset and Programming Custom Cartridge Replaceable Battery Muffler Genie Chapter 5 OPERATING INSTRUCTIONS...
  • Page 13: Setting Up The Cartridge

    • Remove the plug from the top outlet port (a) of the cartridge. (a) Outlet Plug (b) Air-stem Plug Insert the airstem into the air-stem port in the cartridge head. Rotate air stem to locked position. Genie Chapter 5 OPERATING INSTRUCTIONS...
  • Page 14 CORRECT: INCORRECT: Reattach if needed If the appliance has been previously programmed activate preferred setting. If not (see Programming the Appliance), press so the backlight turns on, snap and lock the door. Genie Chapter 5 OPERATING INSTRUCTIONS...
  • Page 15: Programming The Appliance

    24/7 Mode. until 24/7 • If you want Genie to run continuously — 7 days a week, 24 hours a day — press is displayed above the time. If not, skip to Step 5. Set Program Mode.
  • Page 16 The appliance will automatically switch from Set Program to Run Program after 30 seconds of until Set Program is displayed above the time. You may review the inactivity, or you can press while the appliance is in Run Program mode. programs by pressing Genie Chapter 5 OPERATING INSTRUCTIONS...
  • Page 17: Using The Online Sd Card Programming Tool

    3. Press the reset button, and the five buttons will light in sequence from left to right. 4. The buttons will light alternately. for one second, and the display will show LOAD for 5. Press and hold Genie Chapter 5 OPERATING INSTRUCTIONS...
  • Page 18 1. Insert a FAT32 formatted SD card, with the label side down. 2. Press the reset button, and the five buttons will light in sequence from left to right. 3. The buttons will light alternately. Genie Chapter 5 OPERATING INSTRUCTIONS...
  • Page 19: Setting Scent Intensity

    Scent Control If you followed the Room-Size Chart or S3 Tool, you have set Genie to the low end of the range for your room size. If after one hour you feel the scent is not detectable, increase the setting by about 10%.
  • Page 20: Chapter 6: User Maintenance

    Appliance malfunctions are not intended to be serviced in the field, however the pump is field replacable. If there is no plume after following the procedure outlined above or there is any excessive noise level, then the appliance must be replaced with a new one. Genie Chapter 6 USER MAINTENANCE...
  • Page 21: General Care

    Do not drop Genie on the floor. Do not drop it in or position it near water. • Do not paint or otherwise try to alter the color of the outer cover. Genie is available in any color. • When shipping, pack in the original box and place it in an outer cardboard box.
  • Page 22: Chapter 7: Applications

    Applications Genie is used to enhance indoor air quality by neutralizing odors or introducing and maintaining a scent in the air or both at the same time. This is accomplished by blending ultra-low concentrations of odor neutralizers and fragrance ingredients (“Air-Treatment Agents”) into the air. In fact, Genie is fully effective with air concentrations of Air-Treatment Agents less than 1 part per million (ppm).
  • Page 23: Product Marketing

    Scent is the main feature of these products. Using Genie to present that scent to a customer is the best way to present and sell the product. In this way, Genie delivers a true and complete experience of the scent to clients and passersby without intrusion or sales associate intervention.
  • Page 24: Aromatherapy And Performance Scenting

    The benefits include reduced errors in routine functions, increased employee sense of well being, higher morale, improved customer service and overall improved productivity. Genie™ and Prolitec aromatherapy chemistry can help make a workspace a more comfortable and appealing place to be. As examples of the positive effect of aromatherapy on the workplace, below are results of several relevant studies: •...
  • Page 25: Chapter 8: Important Safety Instructions

    • Never put your nose to the output of the Genie. Within 12 inches of the output, the fragrance is highly concentrated. The improper inhalation of high concentrations of fragrance may cause irritation including watery eyes, headache, cough and upper respiratory discomfort.
  • Page 26: Fragrance Cartridge Precautions

    Fragrance Cartridge Precautions • Use only AirQ by Prolitec fragrance cartridges. • Read the Consumer Product Safety Information Sheet and the Material Safety Data Sheet provided with each shipment of Cartridges. Insure that these information sheets are available for review by employees.
  • Page 27: Chapter 9: Frequently Asked Questions

    Where can I place Genie? Genie should be placed on a wall where it can take full advantage of the natural air currents in the space as determined by a smoke test or as known by you. Accessory kits can be ordered for placing the unit on a ceiling (track light) or table top.
  • Page 28 The more expensive aerosols can produce a very pleasant scent, but only for a few minutes and in very high concentrations just in the area they were sprayed. Genie is what is known as a “continuous action” air freshener. Genie is programmed to deliver an evenly distributed scent throughout the room.
  • Page 29: Chapter 10: Specifications

    Specifications Dimensions Genie Appliance 11” x 7.5” x 3” (27.9 cm x 19.1 cm x 7.6 cm) Weight 5.2 lbs (2.4 kg) withnfull 500mL cartridge Power Supply Input — 100 – 240VAC, 0.6A max, 50/60 Hz Protection — Switching power supply Output —...