Advertisement

P ERFEC T LY S C E N TE D E N V IR O NM E N TS
AirQ 270 TT/WM
Updated: 2019-06-13

Advertisement

Table of Contents
loading

Summary of Contents for Prolitec AirQ 270 TT

  • Page 1 P ERFEC T LY S C E N TE D E N V IR O NM E N TS AirQ 270 TT/WM Updated: 2019-06-13...
  • Page 2: Table Of Contents

    Contents Chapter 6: USER MAINTENANCE Cartridge Change Chapter 1: About AQ270 Cartridge Change Maintenance Checklist Items Chapter 2: Unpacking Changing an Appliance Chapter 3: MOVING AND STORAGE General Care INSTRUCTIONS Chapter 7: Applications Chapter 4: INSTALLATION Ambient Scenting General Product Marketing Location Odor Control Service Area...
  • Page 3 About AQ/PS/RZ 270 Welcome to a whole new world of air treatment from Prolitec, the technology leader in air care with scent. The AQ270 appliance is the most advanced commercial air-treatment system on the market today. It is the world’s first fully adjustable commercial air-treatment system engineered to serve indoor spaces ranging in size from 100 to 15,000 cubic feet (6 to 425 cubic meters).
  • Page 4: Chapter 2: Unpacking

    Unpacking Remove AQ270 from the container. The following items should be included: 1. AQ270 Appliance 2. Power Supply 3. Key 4. Mounting Hardware 5. Installation Template AirQ 270 Chapter 2 Unpacking...
  • Page 5 MOVING AND STORAGE INSTRUCTIONS 1. Remove the cartridge. 2. Unscrew and remove the two screws on the right. 3. Lift the appliance upward, off the mounting screws. 4. Unplug the appliance. 5. Store at -4°F (-20°C) to 158°F (70°C), 5% to 95% humidity AirQ 270 Chapter 3 MOVING AND STORAGE INSTRUCTIONS...
  • Page 6: Chapter 4: Installation

    Installation General Location AQ270 is designed for permanent installation on wall surfaces over a 110 to 240V outlet, or used as a table- or shelf-top unit. Service Area The service area range of AQ270 is from 100 to 15,000 cubic (6 to 425 cubic meters). Of course this can vary significantly depending on airflow, number of fresh air changes per hour, temperature, humidity and desired service interval.
  • Page 7: Estimating Cartridge Life

    Estimating Cartridge Life Estimating how long a cartridge will last and the number of days between services is critical to performing an installation that can be serviced efficiently. This includes determining the number of AQ270s needed for a space. Please refer to AirQ’s ‘S3 (Sizing, Service & Success) Tool,’ available at AirQ Tools.
  • Page 8: Appliance Location

    AQ270 can use, rather than fight, the natural air currents in a room. 2. Air currents in a room are determined by using a SMOKE TEST KIT available from Prolitec or any source of smoke or vapor, such as a candle or match.
  • Page 9: Positioning The Installation Template

    Step 2 – Mounting Kit, Parts and Tools The mounting kit provided with AQ270 includes an installation template and 4 long round-head screws and 4 wall anchors suitable for plastered drywall. If you have another surface you will need to get anchors suitable for the wall material and screws that work with these anchors.
  • Page 10: Installing The Anchors

    Step 4 – Installing the Anchors Use an electric drill to make a 1/8” hole at the exact location you marked. This will serve as a guide for the anchors. Use a hammer to tap the anchors in far enough so they stay well in position. Then screw them straight into the drywall.
  • Page 11: Final Two Screws

    Step 7 – Final Two Screws Secure the appliance to the wall with the final two screws. Step 8 – Replacing the Cover After cartridge installation unit programming, replace the cover and lock it, storing the key in a known location. AirQ 270 Chapter 4 Installation...
  • Page 12: Chapter 5: Operating Instructions

    OPERATING INSTRUCTIONS Features and Controls Lock Lock Cover User Interface Locking Air Stem and Air Hose Reset and Programming Custom Replaceable Cartridge Battery Muffler AirQ 270 Chapter 5 OPERATING INSTRUCTIONS...
  • Page 13: Setting Up The Cartridge

    Setting Up the Cartridge 1. Use the key to unlock and open the door. 2. Prepare the cartridge. • Remove the big plug from the air-stem port (b) on the flat surface (back side) of the cartridge. • Remove the plug from the top outlet port (a) of the cartridge. (a) Outlet Plug (b) Air-stem Plug Insert the airstem into the air-stem port in the cartridge head.
  • Page 14 Place cartridge in recess. If the muffler does not fit as shown, then remove the air hose assembly and reattach as shown.. CORRECT: INCORRECT: Reattach if needed If the appliance has been previously programmed activate preferred setting. If not (see Programming the Appliance), press so the backlight turns on, snap and lock the door.
  • Page 15: Programming The Appliance

    Programming the Appliance Unlock and remove the front. Turn on the power by pressing on the control panel. Set the Clock. • Press to cycle through the modes to the options mode. The day of the week will blink. • Adjust the day forward or backward using •...
  • Page 16 • Press to set the intensity and the day of the week will blink. • Adjust the day of the week forward or backward using HINT: In addition to individual days, you can also set “all days,” “week days,” or “weekend days.” to set the day of the week.
  • Page 17: Using The Online Sd Card Programming Tool

    Using the online SD card programming tool The online SD card programming tool can be found at http://airqtools.com/sdcard/ 1. Multiple programs sets can be created, which are unique to the user, and stored in a list. 2. Create a program set using the create program button. •...
  • Page 18 about ten seconds. 6. The five buttons will light in sequence from left to right. 7. Remove the SD card; the display will show the currently loaded firmware version and the pump will run for one second. 8. Press to turn on the power. 9.
  • Page 19: Setting Scent Intensity

    for one second, and the display will show SAVE for 4. Press and hold about ten seconds. 5. The five buttons will light in sequence from left to right. 6. Remove the SD card; the display will show the currently loaded firmware version and the pump will run for one second.
  • Page 20: Chapter 6: User Maintenance

    USER MAINTENANCE Cartridge Change When the reservoir is empty the cartridge needs to be changed. The change process is simple. Best practice is to wear gloves when manipulating the cartridge. 1. Unlock and remove the front cover. 2. Turn off the power by pressing the power button. 3.
  • Page 21: General Care

    General Care • AQ270 is an electronic appliance. Treat it like a laptop. • Do not place or store AQ270 or its cartridges in extreme heat (more than 130˚ F) or in freezing temperatures. • Do not drop AQ270 on the floor. Do not drop it in or position it near water. •...
  • Page 22: Chapter 7: Applications

    There are four basic applications for AQ270: ambient scenting, product marketing, odor control and aromatherapy. These applications are different in terms of their objectives, but they all employ the same combination of Prolitec’s proprietary air-treatment chemistry and AQ270 computer-controlled delivery system.
  • Page 23: Product Marketing

    AQ270 and Prolitec’s proprietary odor-remediation chemistry are capable of blocking the human ability to detect most malodors and replacing these odors with pleasant scents. Prolitec’s proprietary air-treatment chemistry and the accompanying computer-controlled delivery system are rapidly becoming the standard solution for difficult odor issues in several industry sectors.
  • Page 24: Aromatherapy And Performance Scenting

    The benefits include reduced errors in routine functions, increased employee sense of well being, higher morale, improved customer service and overall improved productivity. AQ270™ and Prolitec aromatherapy chemistry can help make a workspace a more comfortable and appealing place to be. As examples of the positive effect of aromatherapy on the workplace, below are results of several relevant studies: •...
  • Page 25: Chapter 8: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS – SAVE THESE INSTRUCTIONS Appliance Precautions WARNING – When using electric products, basic precautions should always be followed, including the following: • Read all the instructions before using the product. • Children should be supervised not to play with the appliance. •...
  • Page 26: Fragrance Cartridge Precautions

    Fragrance Cartridge Precautions • Use only AirQ by Prolitec fragrance cartridges. • Read the Consumer Product Safety Information Sheet and the Material Safety Data Sheet provided with each shipment of Cartridges. Insure that these information sheets are available for review by employees.
  • Page 27: Chapter 9: Frequently Asked Questions

    Frequently Asked Questions (FAQs) How does AQ270 work? AQ270 uses a patented technology to convert liquid fragrance compounds into tiny droplets less than 1/100th the diameter of a human hair. By comparison, an aerosol droplet is 100 times bigger and 1,000,000 times heavier. AQ270 droplets present 100 times more surface area to the air being treated, which means much less fragrance is used to create the scent effect.
  • Page 28 How does AQ270 differ from aerosol room fresheners? The more expensive aerosols can produce a very pleasant scent, but only for a few minutes and in very high concentrations just in the area they were sprayed. AQ270 is what is known as a “continuous action”...
  • Page 29: Chapter 10: Specifications

    85% or less Liquid Capacity 500 mL cartridges Service Area Up to 15,000 cu. ft. (425 m ) served Prolitec, Incorporated 1235 W. Canal Street Milwaukee, WI 53223 1-866-387-4333 www.prolitec.com All contents © 2016-2018 Prolitec, Inc. AirQ 270 Chapter 10 Specifications...

This manual is also suitable for:

Airq 270 wm