Contents Chapter 9: INSTALLATION: Chapter 1: About AirQ 1200 Diffusion via Direct Indoor Fan Chapter 2: Cartridge Life & Room Size Table Installation Kit for Appliance Estimating Cartridge Life Installation Kit for Fan Room-Size Table Pre-installation Checklist Chapter 3: IMPORTANT SAFETY Appliance Positioning INSTRUCTIONS Appliance Installation...
Page 3
About AQ/PS/RZ 1200 Welcome to a whole new world of air treatment from Prolitec, the technology leader in air care with scent. The AQ1200 appliance is the most advanced commercial air-treatment system on the market today. It is the world’s first fully adjustable commercial air-treatment system engineered to serve indoor spaces.
Page 4
The scientists and engineers at Prolitec are committed to the highest ecological and human safety standards. This user guide is easy to read. It is also important to read. AQ1200 is a high-performance appliance that, installed and used correctly, will meet the most demanding requirements.
Cartridge Life & Room Size Table Estimating Cartridge Life Estimating how long a cartridge will last and the number of days between services is critical to performing an installation that can be serviced efficiently. This includes determining the number of AQ1200s needed for a space.
IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS – SAVE THESE INSTRUCTIONS Appliance Precautions WARNING – When using electric products, basic precautions should always be followed, including the following: • Read all the instructions before using the product. • Children should be supervised not to play with the appliance. •...
& Fragrance Cartridge Precautions • Use only AirQ by Prolitec fragrance cartridges. • Read the Consumer Product Safety Information Sheet and the Material Safety Data Sheet provided with each shipment of Cartridges. Insure that these information sheets are available for review by employees.
Page 8
Appliance & Controls Injector Hose Hose Clamp Control Display Hose Connector Control Buttons Nozzle Program First Selector Stage Air Filter DC Power Jack (see below) Recyclable Cartridge Battery Auxiliary DC Power Jack AQ/PS/RZ 1200 Chapter 5 Appliance & Controls...
USER MAINTENANCE Changing the Cartridge Unlatch and open the door to access the cartridge: The door should be opened only to perform a cartridge or programming change. When in use, the door must be closed. Press POWER button to turn appliance OFF. Remove air nozzle (located on the side of the cartridge head) by rotating 90 degrees and pulling towards you.
Air Filters and check valve (every 6 months or sooner depending on use) AQ1200 is equipped with two stages of air filtration and a check valve system. The first stage is a sintered filter (PN 10417). It is can be unscrewed and washed with clean water as needed.
Battery Replacement (approximately every two years) (Requires 3 Volt CR2032 Lithium Battery, PN 8111) Unlatch and open the door to access the enclosure. Using a pair of tweezers or needle-nose pliers, remove battery from the center opening of the battery grommet.
OPERATING INSTRUCTIONS Unit Programming Unlock and open the door Turn on the power by pressing ON/OFF button in the upper left corner of the control panel. Set the Clock • Turn the dial to Set Clock. The day-of-week icon will blink. •...
HINT:To set same programs for Monday to Friday, you may set the programs for every day first and then disable Saturday and Sunday. You may review the programs by doing the same as in programming. Just beware not to accidentally set the every day programs as this will also set and change the programs of all the days.
INSTALLATION: Diffusion via HVAC System Installation Kits Installation Kit for Appliance (included) One (1) AQ1200 appliance (not pictured) with: Four (4) drywall anchors for mounting in drywall Four (4) lead anchors for mounting in concrete Four (4) screws and (4) washers for mounting in drywall and concrete Four (4) #10 self-tapping sheet metal screws for mounting in sheet metal Plume connector: A: (1) Tubing assembly;...
Installation Kit for HVAC System Diffusion (included) One (1) Prolitec injector tube for diffusion into HVAC system Three (3) #10 self-tapping sheet-metal screws for mounting the injector tube in sheet metal Five (5) feet of injector hose HVAC Pre-installation Checklist This checklist should be completed before the install date.
Plume output can pass over hot water, steam, chilled water, and DX coils. Open gas flames should absolutely be avoided. If installation must be over gas heated coils or open gas flames, contact Prolitec Technical Support. The best location for the Appliance is below the injector tube (Fig.
Fig. 16 CORRECT INCORRECT Appliance Installation The appliance is wall-mounted. Place the appliance onto the desired location on the wall or AHU and ensure that it is level. Fasten the appliance to the wall or AHU using necessary screws. Connect the power cord to a junction box or attach an AC plug to the cord and connect to a nearby outlet.
Injector Tube Installation The injector tube is installed directly into the AHU or ductwork. Its orientation can be adjusted relative to airflow. • For installations into the negative/suction side of the AHU fan, orient the tube with the elbow pointed upwards, so that any plume condensation will drip back down the tube.
INSTALLATION: Diffusion via Direct Indoor Fan (Product# AQ1200-FAN) Installation Kits Installation Kit for Appliance (included) One (1) AQ1200 appliance (not pictured) with: Four (4) dry wall anchors for mounting in drywall Four (4) lead anchors for mounting in concrete Four (4) screws and (4) washers for mounting in drywall and concrete Four (4) self-tapping sheet metal screws for mounting in sheet metal Plume connector: A: (1) Tubing assembly;...
Installation Kit for Fan (accessory sold separately) One (1) Prolitec Diffusion fan and cable for direct indoor diffusion Three (3) drywall anchors for mounting fan onto dry wall Three (3) lead anchors for mounting in concrete Three (3) screws for mounting in drywall and concrete...
Pre-installation Checklist This checklist should be completed before install date. Confirm the area to be targeted for air treatment. Confirm the general direction of ambient air flow in the area and position the machine so that the plume will be more evenly distributed and carried by the natural air flow. Determine the number of machines required, which is the total cubic feet to be served divided by a maximum of 150,000.
Diffusion Fan Installation Fig. 3 Fig. 4 Fig. 5 Fig. 6 The diffusion fan is positioned directly above the appliance hose output port located on the top left of the appliance but no more than 4-1/2 feet above it. (Fig. Use the diffusion fan assembly as a template to mark the location of the mounting holes.
Page 23
Fig. 8 Fig. 9 Fig. 10 Fig. 11 Run Diffusion Fan cable inside the raceway (Fig. 10), fold the raceway into a square and snap the raceway cover closed. (Fig. 11) If needed, use a flat-head screw driver to push in the side wall of the cable raceway.
Troubleshooting Condition Causes Solutions Power light off. The Appliance is not Make sure the power connection is operational. plugged in or the plug has Verify that the power button light is blue when no power pressed. Unit does not start Back-up battery not Verify the protective yellow battery tab has been automatically after a...
Page 25
Condition Causes Solutions The power light is on The output tube may be Remove the hose from the output tube leaving and the compressor blocked. the Cartridge in place in the appliance. Turn the can be heard but no appliance on so you can hear the compressor. Use fragrance detected.
Do not operate AQ1200 in very dusty areas that may cause the air intake to clog. • Do not move or transport an appliance with a cartridge installed. • Please call Prolitec Customer Service at 866.387.4333 for return shipping instructions or questions. AQ/PS/RZ 1200 Chapter 11 General Care & Customer Support...