Managing DSL
2
View the statistics.
Parameter
Operational State
Data Rate
DSP Version
Last Failed
Remote Coefficient A
Remote Coefficient B
Transmission Power
Receiver Gain
Local SNR Margin
Framer Sync
36
Description
Valid entries are:
• Handshaking is when the modem is making an attempt to
connect to a device on the other side of the G.shdsl line.
• Training is when the modem is learning the connection
parameters.
• Show Time is the actual connection time.
Bit rate after the ATM headers have been removed.
The modem DSP code can be upgraded—this is the current
version that is running on your system.
Displays the last state reached before start-up failed. This is used
for troubleshooting by technicians.
Displays the remote coefficient for channel A.
Displays the remote coefficient for channel B.
Displays the local transmission power in dB.
Displays the amplifying factor for incoming signal in dB.
Actual value of the current Signal to Noise (SNA) ratio.
Displays the link status.