User instructions
Powerbox type CP-FB-TBOX-SUBD9 is designed for coupling
CP branch lines to CAN networks as laid down in regulations,
the branch lines consisting of CP valve terminals and, where
necessary, CP I/O modules. The Powerbox is designed for CAN
networks having a pin assignment conforming to the CANopen
standard. Coupling of CP branch lines is only possible with
CAN masters that support the CP protocol to the Festo specifi-
cations. These include:
Festo IPC with CAN Bus Module CP81
Jetter Process PLC.
The number of Powerboxes allowed for one CAN network and
the maximum branch line length permitted depends on the
fieldbus protocol and the fieldbus baud rate.
WARNING:
Incorrect installation can cause interference in operation.
Check the following in your CAN Master handbook:
- the max. number of branch lines for your
CAN network
- the max. number of CP modules allowed per branch line
and for the network
- the max. branch line length allowed.
Before installation:
WARNING:
Switch off the following power sources before commencing
installation and maintenance work:
- compressed air supply
- operating and load voltage supplies.
9710NH