3
Performance Tests
70
Electrical connections 8 Mb/s to 155 Mb/s
Use BNC cable P/N 15525A
• Connect 52/155 Mb/s Out (BNC) <=> 52/155 Mb/s In (BNC)
• Connect 2 - 140 Mb/s DS3 Out (BNC) <=> 2 - 140 Mb/s DS3 In
(BNC)
Unbalanced Electrical Connections PDH/DSn 2-140 Mb/s and DS3
Use BNC cable P/N 15525A
• Connect 2 - 140 Mb/s DS3 Out (BNC) <=> 2 - 140 Mb/s DS3 In
(BNC)
Balanced Electrical Connections 2M/DS1
Use 3-pin Siemens cable P/N 15512A and Bantam cable P/N
15670A
• Connect 2M Out (3-pin Siemens) <=> 2M In
• Connect DS1 Out <=> DS1 In
Ethernet Loopback Connections (Option Dependent)
• Use standard category 5 patch cords for the 10/100 Mb/s
Ethernet loopbacks. No crossover is required as this is
handled internally. These patch cords are supplied with the
instrument, Part Number J2126-65021.
• Use duplex SC optical patch cord (Tx crossed-over to Rx and
Rx crossed-over to Tx). This patch cord is supplied with the
instrument when 1 Gb/s Ethernet is fitted, Part Number
1005-1110 (850 nm) (Tyco Electronics Corp/AMP 504971-1),
or 1005-1111 (1310 nm) (Tyco Electronics Corp/AMP
492019-1).