7. Reassemble the inner door assembly using the six screws on the outside of the door.
NOTE: Remember that the lip on the door gasket mounting plate must fit into the channel on the inside
edge of the gasket to insure a proper seal.
Procedure—To Adjust Gasket to Unit:
To prevent steam leaks around the door, adjust the gasket tension to cavity. Adjust the gasket by
loosening the six screws on top and bottom of door, move inner door plate in or out, left side or right
side, and tighten the six screws.

Exterior Panel Removal

WARNING:
To prevent hazard in servicing the cooker, be certain that the steam supply boiler is shut down, the
cold water shut-off valve is closed, and the electrical disconnect circuit breaker for the cooker/boiler
unit is off before removing side panels.
Access to all internal plumbing and electrical assemblies is from the right side and right front. The left-
side panel is removed by removing the bottom screw and pushing up on the panel until the lower lip
disengages the frame. The panel is shown as item #25 in Figure 7 on page 28. The electric control panel,
shown in Figure 10 on page 32, may also be removed as a unit by removing screws and pulling the panel
forward. Removal of the control panel is completed by unplugging interconnecting wiring at the pin
housing.

Steam and Water Solenoid Valve Replacement

Replacements for the 1/2-inch steam solenoid valves and the 1/4-inch water valves are available as
complete units from Market Forge Authorized Service Agencies. It is necessary to replace an entire
steam valve when the coil is faulty or the diaphragm ruptures. Replacement coils are available for the
water valves. The valves are accessed as explained in Exterior Panel Removal shown above.