ASSEMBLY

The Pressureless Cooker is factory-mounted on a cabinet base containing either a steam boiler or direct
steam connection controls for the cooker. The assembled unit is shipped bolted to a skid, with cabinet
feet in a separate container. Steps required for assembly are as follows:
1. Remove the four bolts that fasten the equipment frame to the skid.
2. Install feet in threaded mounting locations of the cabinet frame.
3. Mount the four pan support racks in brackets and studs inside cooking compartments.
4. Attach panels to lower cabinet. Detailed instructions are enclosed with the panels.
5. Attach the drip trough on studs located on the face of the unit.

SETTING IN PLACE

Level the unit in final location by turning the adjustable feet. Using the cabinet top as a reference, obtain
level adjustment left-to-right and front-to-back.

MECHANICAL CONNECTIONS

Since the Pressureless Cooker is interconnected at the factory to the steam boiler or direct steam
plumbing, no field connections to the cooker are required. All electrical and plumbing connections are
routed to the steam boiler cabinet through the 6-inch-high space between the floor and the bottom
edge of the cabinet frame. Connection locations for the cooker mounted on steam boilers of electric,
gas, and steam coil utility and direct-connected steam are shown in separate installation instructions for
each.

WATER CONNECTIONS

Before connecting water to this unit, have water supply analyzed to make sure that hardness is no
greater than 2.0 grains per gallon and pH level is within the range of 7.0–8.5. Water that fails to meet
these standards should be treated by the installation of a water conditioner.
EQUIPMENT FAILURE CAUSED BY INADEQUATE WATER QUALITY IS NOT COVERED UNDER WARRANTY.
CAUTION: PVC or CPVC are not acceptable materials for drains.

INSTALLATION CHECK-OUT

Check-out procedures for the cooker mounted on steam boilers of electric, gas, and steam coil utility or
direct-connected steam are given in separate installation instructions for each. Refer to Cooker Check-
Out on next page for the correct procedure. If the cooker fails to perform as described, consult the
Trouble-Shooting Guide for corrective action. If difficulty arises with the boiler, reference the separate
service and parts manual for that equipment.
Before making this check-out, the operator must be thoroughly familiar with the operating procedures
and with the function of each control. Refer to the section on Operation and Figure 2, Controls and
Indicators for identification of controls required in the following procedures.