Cleaning Procedure

After each period of daily operation (more frequently as required to maintain cleanliness), the cooker
should be thoroughly cleaned by completing the following steps:
1. Remove left- and right-side pan supports, baffles, and drain screens by lifting up and off
mounting studs. Wash with a mild detergent. Rinse and set aside for reassembly.
2. Wash cooking compartment interior using a mild detergent and water. Rinse and dry
thoroughly.
3. Replace pan supports, baffles, and drain screens in compartment and leave door open.

REPAIR AND REPLACEMENT

The Illustrated Parts List section of this manual contains a listing of all replacement parts and associated
exploded views of the ST-24 cooker. In most cases, disassembly procedures will be obvious from the
exploded views. Instructions follow for the procedures that are not readily apparent.

DOOR LATCH TENSION ADJUSTMENT

Procedure:
1. Open the cooking compartment door.
2. Remove the control panel by removing the eight mounting screws and disconnecting the wire
plug and restraining wire.
3. Tighten both nuts down until the springs are fully compressed.
4. Back each nut off 1/2 turn.
5. Remount the control panel, reconnecting wire plug and restraining wire.

Door Handle Tension Adjustment

Procedure:
1. Open the cooking compartment door.
2. Remove the six screws and washers from the top edge and bottom edge of the door.
3. Remove the inner door gasket mounting plate assembly from the outer door. Do not
disassemble these three components—remove them as an assembly.
4. Tighten both nuts down until the springs on the outer door are fully compressed.
5. Back each nut off 1/2 turn.
6. Remount the inner door gasket mounting plate assembly by assembling the six screws and
washers.

Door Gasket Replacement

The cooking compartment door gaskets are made of a silicone-type rubber material that is very durable
but subject to wear during normal operation. Should the gasket leak, readjust the door gasket to the
unit or replace it.
Procedure—Replace Gasket:
1. Open the cooking compartment door.
2. Remove the six screws on the outside of the door, and remove the inner door assembly.
3. Remove the eight nuts from the door gasket mounting plate on the inside of the inner door
assembly.
4. Remove the door gasket mounting plate and the door gasket.
5. Install the new door gasket (see Figure 9 on page 31 for part number) to the mounting plate.
6. Reassemble the mounting plate with gasket to the inside of the inner door assembly using the
eight nuts.
CAUTION: SHUT OFF MAIN ELECTRICAL POWER TO UNIT!