Summary of Contents for Market Forge Industries TS-3E
Page 1
TS-E TURBO STEAM ELECTRIC COUNTERTOP CONVECTION STEAMER PARTS AND SERVICE MANUAL EFFECTIVE JUNE 12, 2017 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified are not available. ERRORS: Descriptive and/or typographic errors are subject to correction. MARKET FORGE Telephone: (802) 658-6600 Fax: (802) 860-3732 www.marketforge.com...
TROUBLESHOOTING GENERAL TROUBLE-SHOOTING GUIDE PROBLEM PROBABLE CAUSE REMEDY COOKING INDICATOR LIGHT a. Main power circuit breaker tripped. a. Locate external circuit breaker for incom- FAILS TO LIGHT WITH TIMER ing power and place in ON position. b. Door interlock switch contacts not SET.
Page 4
TROUBLESHOOTING Timer Motor Buzzer A defective timer motor will cause continuous operation in If the buzzer does not sound at the termination of the the TIME mode, with the timer dial failing to return to the operator-selected timer setting (timer dial returned to “0 “0 - Minute”...
ELEMENT BLOCK REPLACEMENT 1. Disconnect power supply. 2. Ensure the unit is cool and empty. 3. Remove the right side panel by removing two screws near the base of the unit. Lift panel up and away to remove and set aside. 4.
FLOOR DRAIN KIT ASSEMBLY ITEM PART NO. DESCRIPTION TS-3E TS-5E 15-7459 3/4” SILICONE HOSE, 5’ LONG 08-1206 HOSE CLAMP 90-8030 1/2” x 3/4” HOSE BARB 10-2863 1/2”, 90° STREET ELBOW, BRASS 97-6211 These parts provide a means of draining the steam generator to a suitable drain or collector. These ports will not complete the connection, additional parts will be needed and may be obtained locally.