Calibration Correction Value A: Rha/Wha; Rha/Wha; Calibration Correction Value B: Rhb/Whb; Rhb/Whb - Panasonic HL-C2 Series User Manual

Ultra high-speed, high-accuracy laser displacement sensor, rs-232c communication control
Hide thumbs Also See for HL-C2 Series:
Table of Contents

Advertisement

1-1-13 Calibration Correction Value a: RHA/WHA

WHA and RHA respectively specify and load the setting of calibration
correction value a for each sensor head.
For the execution procedures of calibration, refer to "1-1-11 Execute
Calibration: WCE".
Command
Read Setting
RHA WHA
% E E # R H A
Header
% E E # W H A
Header
Ex
(1) Setting value of Calibration Correction Value a is loaded.
Request:
Response:
(2) Calibration Correction Value a is set to "+123.456789".
Request:
Response:

1-1-14 Calibration Correction Value b: RHB/WHB

WHB and RHB respectively specify and load the setting of calibration
correction value b for each sensor head.
For the execution procedures of calibration, refer to "1-1-11 Execute
Calibration: WCE".
Command
Read Setting
RHB WHB
% E E # R H B
Header
% E E # W H B
Header
Code
1/2
-950.000000 to +950.000000[mm] 0.000001[mm]
Command
Code
Command
Code
% E E # R H A 1
*
% E E $ R H A +
0
% E E # W H A 1
+
% E E $ W H A *
*
Code
1/2
-950.000000 to +950.000000[mm] 0.000001[mm]
Command
Code
Command
Code
1-11
Chapter 1 Head Command
Setting value
C
BCC
Subdata
*
CR
0
5
.
0
0
0
0
0
0
1
2
3
.
4
5
6
7
8
CR
Setting value
C
BCC
Subdata
Least input
increment
1
FORMAT
CR
BCC
4
FORMAT
1
FORMAT
2
*
*
FORMAT
CR
4
9
*
*
CR
FORMAT
9
FORMAT
Least input
increment
1
FORMAT
CR
BCC
4
FORMAT
1

Advertisement

Table of Contents
loading

Table of Contents