Chapter 2 OUT Command
2-1-23 Execute Analog Scaling: WAS
WAS executes respective analog scaling.
Measurement value A[mm]= a[V], Measurement value B[mm]=b[V]
Set appropriate voltage to any two points A and B.
Execution procedures of analog scaling
1
Set Measurement Value A.
2
Set Measurement Value B.
3
Set Voltage a.
4
Set Voltage b.
2
5
Execute analog scaling by the WAS command.
When analog scaling will be aborted during the procedures due to an
abnormality such as communication error, make sure to transmit "Cancel" of
the command.
Command
Read Setting
% E E # W A S
Ex
Analog Scaling is executed.
Request:
Response:
2-1-24 Analog Output at Alarm: RAA/WAA
WAA and RAA respectively specify and load the setting of analog
output at alarm for each OUT.