Chapter 5 Buffering Command
For trigger mode:
Loads the measured data from the actual trigger generated point to the
delayed trigger point that has been set for this function.
For sample trigger mode:
Starts accumulation of the measured data from the delayed trigger point that
has been set for this function after the trigger was generated. The function
ignores even if a new trigger is generated during the trigger delay operation.
When the buffering rate is already set, the trigger delay is counted with the
extended sampling in accordance with the setting.
8
Specify the trigger point.
When the buffering mode is set to trigger mode, the measurement data can be
loaded by setting the data at the trigger generated as a trigger point.
(Command description
Setting range is 1 to setting "accumulation amount".
The initial value is set to "10000".
· If the "trigger point" is set to a larger value than the setting "accumulation
amount", accumulation cannot be started.
5
· When the "Trigger Delay" function is set, the measurement data from the trigger
delayed data point after the setting trigger is generated can be loaded.
8
Specify the sample trigger accumulation amount.
When the buffering mode is set to sample trigger mode, the sample trigger
accumulation amount can be set at every trigger generation.
(Command description
RSR/WSR")
Setting range is 1 to setting "accumulation amount". The initial value is set to "1".
Be sure to set the sample trigger accumulation amount so that (accumulation
amount) ÷ (sample trigger accumulation amount) is an integer value.
2. Buffering start
Start buffering operation.
(Command description
1
Set Buffering Operation to "Start".
* The initiation of accumulation differs depending on the buffering mode
selected.
3. Accumulation start
Start data accumulation.
The initiation conditions of accumulation differ on the buffering mode
selected.
"5-2-8 Trigger Point: RTP/WTP")
"5-2-9 Sample Trigger Accumulation Amount:
"5-2-10 Buffering Operation: RBS/WBS")