Transparent Object: Rmn/Wmn - Panasonic HL-C2 Series User Manual

Ultra high-speed, high-accuracy laser displacement sensor, rs-232c communication control
Hide thumbs Also See for HL-C2 Series:
Table of Contents

Advertisement

2-1-2 Transparent Object: RMN/WMN

WMN and RMN respectively specify and load the setting of transparent
object for each OUT.
The commands are available while "Transparent Object" is selected in
"Output Selection". Select the target surface(s) for measurement.
Command
Read Setting
RMN
WMN
% E E # R M N
Header
% E E # W M N
Header
Ex
(1) Setting of Transparent Object is loaded.
Request:
Response:
(2) Transparent Object is set to "1st Surface - 4th Surface".
Request:
Response:
Code
Subdata
3/4
Command
Code
Command
Code
% E E # R M N 3
% E E $ R M N 0
% E E # W M N 3
% E E $ W M N *
2-3
00000
00001
00002
00003
00004
Upper Limit Surface
00005
1st Surface - 2nd Surface
00006
1st Surface - 3rd Surface
00007
1st Surface - 4th Surface
00008
1st Surface - Upper Limit Surface
00009
2nd Surface - 3rd Surface
00010
2nd Surface - 4th Surface
00011
2nd Surface - Upper Limit Surface
00012
3rd Surface - 4th Surface
00013
3rd Surface - Upper Limit Surface
00014
4th Surface - Upper Limit Surface
CR
BCC
Subdata
*
*
CR
0
0
0
0
*
*
CR
0
0
0
0
7
*
*
*
CR
Chapter 2 OUT Command
Description
1st Surface
2nd Surface
3rd Surface
4th Surface
1
FORMAT
CR
3
FORMAT
BCC
1
FORMAT
1
FORMAT
3
CR
FORMAT
9
FORMAT
2

Advertisement