Dual-Plane Self-Calibration Procedure
The Dual-Plane Self-Calibration Procedure ensures the Balancer is producing accurate readings by
aligning the software with the existing spindle positions and hardware on the Balancer.
Before performing the Dual-Plane Self-Calibration Procedure, ma ke sure the Balancer is anchored to
the floor and that the shaft and centering cones are clean and undamaged. Dirt or damage can cause
inaccurate readings.
Important:
You will need a steel Wheel with a Tire of a commonly balanced size for this procedure. The Wheel
must already be fully balanced.
To perform the Dual-Plane Self-Calibration Procedure:
1. Mount an already balanced Wheel on the Balancer.
2. Enter the correct Distance, Width, and Diameter values for the Wheel into the Balancer.
3. Press and hold Start and R until CAL | CAL appears on the Inner and Outer Windows and the
Indicators under those windows stop flashing.
4. Lower the Hood to start a balancing session.
The Wheel spins briefly, then stops.
3.50 appears in the Inner Window (100 if grams are selected) and Add appears in the Outer
Window.
5. Turn the Wheel by hand until the Indicators under the Inner Window are all lit.
6. Add a 3.5 ounce /100 gram Calibration Weight (it's a Clip-On Weight) to the Inner Edge of the
Wheel at Top Dead Center (12 o'clock high).
7. Close the Hood to start a balancing session.
The Wheel spins briefly, then stops.
Add appears in the Inner Window and 3.50 appears in the Outer Window (100 if grams are
selected) and.
8. Turn the Wheel by hand until the Indicators under the Outer Window are all lit.
9. Remove the Calibration Weight from the Inner Edge of the Wheel and add it to the Outer Edge at
Top Dead Center (12 o'clock high).
10. Close the Hood to start a balancing session.
The Wheel spins briefly, then stops.
End appears on the Inner Window and CAL appears on the Outer Window.
11. Remove the Calibration Weight from the Wheel.
The Dual-Plane Self-Calibration Procedure is complete.
Important:
DST30P Wheel Balancer
Pay close attention to this procedure. If not done correctly, the Balancer will not
produce accurate readings, leading to Wheels not being balanced correctly.
If the Dual-Plane Self-Calibration Procedure does not complete successfully, visit
www.bendpak.com/support/, call BendPak Ranger at (805) 933-9970,
or email
support@bendpak.com
for assistance.