Sensor adjustment procedure
Before starting this procedure, connect a USB mouse to the machine.
1.
Press the [Parameter] button in the main screen, to display the Parameter dialog on the
main screen.
2.
Click the [Sensitivity] tab of the Parameter dialog, to display the Sensitivity data.
3.
Note the values of "lgain" and "rgain" on the following screen.
4.
Change the values of "lgain" and "rgain" in the Parameter dialog to "30", then click
Apply, then OK.
Service mode