Fimap Maxima Base E Use And Maintenance Manual

Fimap Maxima Base E Use And Maintenance Manual

Professional scrubbing machines 2017
Table of Contents

Advertisement

MAXIMA 2017
BASE E
PROFESSIONAL SCRUBBING MACHINES
USE AND MAINTENANCE MANUAL
ORIGINAL INSTRUCTIONS DOC. 10077476 - Ver. AA - 01-2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Maxima Base E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fimap Maxima Base E

  • Page 1 MAXIMA 2017 BASE E PROFESSIONAL SCRUBBING MACHINES USE AND MAINTENANCE MANUAL ORIGINAL INSTRUCTIONS DOC. 10077476 - Ver. AA - 01-2018...
  • Page 3: Main Machine Components

    Solution tank filler cap/measuring inlet. Main switch. Solution tank filler tube cap. Squeegee body control lever. Cover cap for FFF “FIMAP FAST FILL” quick coupling kit (optional). Brush head control pedal. Recovery tank. Support hook for recovery tank drainage tube.
  • Page 4: Table Of Contents

    CONTENTS GENERAL SAFETY MAIN MACHINE COMPONENTS ..........3 REGULATIONS CONTENTS .................4 GENERAL SAFETY REGULATIONS .........4 The following symbols are used to indicate any CONNECTION TO THE ELECTRICITY GRID ........5 potentially hazardous situations. Always read EXTENSION CABLES ................5 this information carefully and take the necessary CABLE LENGTH ................5 precautions to protect any people and/or objects that USING THE MACHINE .................6...
  • Page 5: Connection To The Electricity Grid

    CONNECTION TO THE ELECTRICITY GRID DANGER: • To reduce the risk of fire, electric shocks or injury, please read and comply with all the safety instructions and warnings. This machine has been designed to be safe when it is used for cleaning in the manner specified.
  • Page 6: Using The Machine

    USING THE MACHINE DANGER: • In the event of danger, take prompt action by pressing the emergency button on the back of the machine (near the control handlebars). • Never collect gases, explosive/inflammable liquids or powders, nor acids and solvents! These include gasoline, paint thinners and fuel oil (which, when mixed with the vacuum air, can form explosive vapours or mixtures), and also non-diluted acids and solvents, acetones, aluminium and magnesium powders.
  • Page 7 CAUTION: • Children must be supervised to ensure they do not play with the machine. • During machine operation, pay attention to other people and especially to children. • Read the labels on the machine carefully. Do not cover them for any reason, and replace them immediately if they become damaged.
  • Page 8: Deactivation Of The Machine

    DEACTIVATION OF THE MACHINE WARNING: • Always protect the machine against sunlight, rain, and other atmospheric agents, both while it is stationary and while it is functioning. Store the machine in a dry, sheltered place: this machine is only designed for use under dry conditions, and must not be used or stored outdoors in humid conditions.
  • Page 9: Transport

    • If there are any machine operation anomalies, check they are not due to a lack of proper maintenance. Otherwise, request the intervention of authorised personnel or an authorised service centre. • If any parts need to be replaced, always request ORIGINAL spare parts from an authorised dealer or retailer.
  • Page 10: Symbols Used In The Manual

    The descriptions contained in this document are not binding. The company therefore reserves the STORING THE USE AND MAINTENANCE MANUAL right to make any modifications at any time to elements, details, or accessory supply, as considered necessary for reasons of improvement or manufacturing/commercial requirements. The reproduction, The Use and Maintenance Manual must be stored in its special pouch close to the machine, protected even partial, of the text and drawings contained in this document is prohibited by law.
  • Page 11: Technical Data

    TECHNICAL DATA MAXIMA 2017 MAXIMA 2017 MAXIMA 2017 MAXIMA 2017 Unit of TECHNICAL DATA BASE 50 E BASE 60 E BASE 50 E BASE 60 E measurement symbol 230V 230V 110V 110V Rated machine power 1200 1200 Working capacity up to 1275 1513 1275...
  • Page 12: Symbols Used On The Machine

    SYMBOLS USED ON THE MACHINE ATTENZIONE! Machine use warning label: È fatto assoluto divieto di aspirare/raccogliere con questo apparecchio polveri e/o liquidi infiammabili e/o esplosivi o particelle incandescenti. ATTENTION! It is absolutely forbidden to suck/pick up inflammable Located on the rear of the machine, to warn the operator which substances and/or explosive liquid and/or solid substances or aflame particles with this machine.
  • Page 13: Machine Preparation

    CAUTION: during this operation, check there are no people or objects near the machine. MACHINE PREPARATION N.B.: the ramp gradient must not be such as to cause damage to the machine as it goes up. HANDLING THE PACKAGED MACHINE WARNING: secure the device according to the directives in force in the country of use, so that it The machine is contained in specific packaging, and since the packaging cannot slide or tip over.
  • Page 14: Securing The Machine

    NB: the tube must be positioned behind the squeegee lifting chain. ASSEMBLING THE BRUSH (50BT VERSIONS) NB: The squeegee has already been adjusted, but refer to “ADJUSTING THE SQUEEGEE For packaging reasons, the brush is supplied disassembled from the machine. To assemble it on the BODY RUBBER BLADES”...
  • Page 15: Hour Meter

    CAUTION: We recommend handling the power cable with dry hands to avoid serious injury. HOUR METER Go to the driving position, behind the machine. The machine control panel contains the control display, which shows the total usage time. The numbers Switch on the machine by setting the main switch to “I”, press the button (4) (Fig.2).
  • Page 16: Scrubbing Without Drying

    By pushing the dead man's lever (2) the brush motor will start operating and the solenoid valve will distribute detergent solution to the brush (Fig.2). SCRUBBING WITHOUT DRYING During the first few meters check that the amount of solution is sufficient to wet the floor, but not To perform a scrubbing only program, proceed as follows: excessive to exit the splash guard.
  • Page 17: At The End Of The Work

    AT THE END OF THE WORK DRAINING THE RECOVERY TANK At the end of the work, and before carrying out any type of maintenance, perform the following Proceed as follows to empty the recovery tank: operations: Take the machine to the maintenance area. Raise the brush head body and detach the "BRUSH HEAD CONTROL"...
  • Page 18: Cleaning The Recovery Tank

    CLEANING THE RECOVERY TANK CLEANING THE WATER SYSTEM FILTER To clean the recovery tank (without the optional tank cleaning kit), proceed as follows: To clean the water system filter, proceed as follows: Take the machine to the maintenance area. Take the machine to the maintenance area. Make sure the machine has been secured (see the section titled “SECURING THE MACHINE”).
  • Page 19: Replacing The Brush Head Brush (60Bt Versions)

    ADJUSTMENT INTERVENTIONS REPLACING THE BRUSH HEAD BRUSH (60BT VERSIONS) The good condition of the brush guarantees better cleaning of the floor, as well as a longer brush head ADJUSTING THE SQUEEGEE BODY RUBBER BLADES gearmotor lifespan. To replace the brush, proceed as follows: Careful adjustment of the squeegee body rubber blades guarantees better cleaning of the floor.
  • Page 20: Choosing And Using The Brushes

    The undersigned manufacturer: Used on all types of floors. Good resistance to wear and tear, and hot water (no greater than 50°C.). FIMAP spa The polypropylene is non-hygroscopic and therefore retains its characteristics even when working in Via Invalidi del Lavoro, 1 wet conditions.
  • Page 21: Troubleshooting

    TROUBLESHOOTING This chapter lists the most common problems linked with the use of the machine. If you are unable to resolve the problems with the information given here, please contact your nearest assistance centre. PROBLEM POSSIBLE CAUSE SOLUTION The main switch is set to “0”. Make sure the main switch is on “I”.
  • Page 22 NOTE...
  • Page 24 FIMAP spa - Via Invalidi del Lavoro, 1 - 37059 S. Maria di Zevio - Verona - Italy Tel. +39 045 6060411 – Fax +39 045 6060417 – E-mail:fimap@fimap.com www.fimap.com...

Table of Contents