11.

ELECTRICAL CONNECTIONS

Wire up as shown in Fig. 8
SLAVE-B EQUIPMENT
Attention:
observe the indicated polarity on
the BUS connection.
For connection of photocells, see par. 11.2
*
11.1
Description of J1 terminal board
Tab. 1 - Description of accessories connection
Terminal
1
OPEN A
2
OPEN B
3
STOP
4
FSW OP
5
FSW CL
6
BUS
7 - 8
+
9 - 11
W.L.
10 - 11
LAMP
12 ÷ 15
-
(1)
If you are not using any accessories, connect the terminal to earth (terminals 12 - 15).
Note: when the automated system is idle, the power supply (+24 V) to accessories is disabled.
Description
(opening command for leaves 1 and 2) Device with NA contact (e.g. key operated push-button)
(opening command for leaf 1)
(gate lock command)
(Opening safety devices contact)
(Closing safety devices contact)
(MASTER-B - SLAVE-B connection)
(positive for 24V power supply)
(Power supply to indicator light)
(Power supply to flashing lamp)
(negative for 24Vdc power supply)
Domo
Motor
Device with NA contact (e.g. key operated push-button)
Device with NC contact.
Photocells (e.g. SAFEBEAM)
Photocells (e.g. SAFEBEAM)
Accessories MAX total absorption of 150mA
FAACLIGHT 12V flashing lamp
21
MASTER-B EQUIPMENT
*
Connected accessory
/
12V - 0.5W lamp
/
Domo
Motor
Fig. 8
(1)
(1)
(1)