8.
WARNINGS
Attention: Before attempting any job on the control board (connections, maintenance), cut out electric power and the
battery.
-Install, upstream of the system, a differential thermal breaker with adequate tripping threshold.
-Always separate 230VAC power cable from control and safety cables (push-buttons, receiver, photocells, etc.). To avoid
any electric noise, use separate sheaths or a shielded cable (with earthed shield).
SLAVE-B EQUIPMENT
J2
Note: if not using the transformer supplied by FAAC, make sure that the secondary winding is 12Vac - 16VA.
*
9.
SLAVE-B BOARD LAYOUT
J1, J5, P1, P2 and LED are not present on the SLAVE-B board,
and the other elements have the following functions.
F1
Battery and motor fuse F20A
J2
Bus connection terminal board
J3
Motor connection terminal board
J4
Battery connector
Programming LED
Voltage ON and
diagnostics LED
transformer
12V battery
J3
J4
F1
MASTER-B EQUIPMENT
( LED P )
12 Vac
*
(optional)
10.
MASTER-B BOARD LAYOUT
P1
Programming push-button: "Function"
P2
Programming push-button: "Value"
F1
Battery and motor fuse F20A
J1
Accessories terminal board
J2
Transformer terminal board
J3
Motor connection terminal board
J4
Battery connector
J5
Minidec/RP Receiver connector
20
P1
P2
J4
J2
F1
J1
J5
J3
Fig. 7