FAAC MASTER-B Manual page 10

Table of Contents

Advertisement

11.3
Connection of MINIDEC, RP cards
Insert the MINIDEC or RP decoding card in the block connector
J5 (Fig. 7), with the components facing up (Fig. 7 shows the
connection of cards RP433DS).
For programming the decoding cards, consult the individual
instructions.
12.
START-UP
12.1
Powering up the system
After making all the cable connections we described previously,
power up the system to enable diagnostics, check of inputs
status and programming.
12.2
Diagnostics
LED "P" (see Fig.7) - visible from outside the enclosure - performs
the diagnostics function. The LED has 4 statuses:
Tab. 2 - Description of LED P status
Steady light
Mains power present and battery charged.
Slow flashing
Mains power not supplied for not more
(lights every
than 5 minutes, with battery charged.
second)
When mains power returns, the LED stays
lighted steadily.
If mains power is still not supplied, the LED
goes off (SLEEP mode).
Mains power present and battery
Rapid flashing
discharged ( gate locked ).
(lights every 250
msec)
The LED continues to flash rapidly until the
battery has recharged sufficiently.
If mains power is not supplied, the LED goes
off (SLEEP mode).
No mains power supplied (SLEEP mode).
Light OFF
Note: in the SLEEP mode, an OPEN pulse is sufficient to move
the gate (with charged battery)
12.3
Status of inputs
The MASTER-B board has a function for checking the status of
inputs on the terminal board.
In all LEDS OFF status (LEDs both with letters and numbers), press
the P2 push-button.
When the LEDs light up, this indicates the inputs status as shown
in Tab. 3.
Fig. 7
Tab. 3 - Description of inputs status LEDs
LEDs
A = Open A
B = Open B
C = Stop
D = Fsw op
E = Fsw cl
1 = SLAVE-B
Notes:
• The status of LEDs with the gate closed at rest is shown in
bold.
• LED 1 is active only when the MASTER-B and SLAVE-B boards
communicate in systems with double-leaf gates and with
the SLAVE-B battery charged.
• In the inputs status function, push-button P1 commands an
OPEN A.
When checks have finished, once again press push-button P2
to exit the inputs status function.
12.4
Programming
These are the basic settings of the MASTER-B board:
MASTER-B board
Function logic:
Pause times:
Opening/closing delay:
Static force:
Speed:
If you wish to execute customised programming (see par. from
12.4.1 to 12.4.6) and time-learning (see par.12.4.7 and 12.4.8)
follow the steps in the next pages.
23
P1
P2
Lighted
Off
(closed contact)
(open contact)
Command active
Command inactive
Command active
Command inactive
Command inactive
Command active
Safety devices disengaged Safety devices engaged
Safety devices disengaged Safety devices engaged
SLAVE-B present
SLAVE-B absent
and active
or inactive
LEAF 1
A4
B1
C3
D3
E2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Slave-b

Table of Contents