2

ELECTRICAL CONNECTIONS

2.1

ELECTRICAL SYSTEM LAY-OUT

B
2.2

DESCRIPTION OF CONTROL UNITS

2.2.1

TECHNICAL SPECIFICATIONS

Programming of functions:
Work time:
Pause time:
Leaf closing delay:
Adjustment of motor force:
Specifications of toroidal transformer 230V~:
Slow-downs:
Clutch device:
F
F
A) Control board enclosure
B) Pull boxes (not supplied)
C) 3x1.5 mm²(2+T) 230V
D) Key-operated selector switch
E) Flashing
E
F) Infrared photocells OPTIONAL
Notes:
D
1) To lay the electrical cables,
2) The figure shows an example
A
B
C
SINGLE MULTI-FUNCTION CONTROL BOARD
Power supply voltage
of the toroidal transformer: 230V - 50/60Hz
Power supply voltage
of the control unit:
Absorbed power:
Motor max. load:
Accessories max. load
Flashing light max. load:
Operating temperature:
Protective fuse:
Function logics:
By Dip-Switch.
Self-learning during programming.
Self-learning during programming.
Two preset levels.
Two preset levels.
Primary 230V~ / sec.13V~ / 150VA
At opening and closing during self-learning.
Electronic clutch adjustable on two preset levels.
OPTIONAL
lamp
12
OPTIONAL
use adequate rigid and/or
flexible sheaths.
of
connection
to
DOMOLINK operator. This
connection layout can be
used also for DOMOSWING.
13V - 50/60Hz
7 W
50 W (per motor)
12 Vdc 150mA
12 Vdc 21W max.
-20°C / +55°C
2
Automatic/
Step-by-step
automatic /
Step-by-step
semiautomatic.
volt